Analysis of the Value of GSI Scanning Combined with “Double-low” Technology in Head and Neck CTA in Middle-aged and Elderly Individuals

Objective: This study aimed to investigate the value of gemstone spectral imaging (GSI) scanning combined with "double-low" technology in head and neck computed tomography angiography (CTA) in middle-aged and elderly individuals. Materials and Methods: One hundred fifty patients who underwent head and neck CTA from February to December 2023 were retrospectively collected and divided into three groups, comprising 50 patients each, according to different scanning modalities; A, B, and C. Groups A and B underwent conventional spiral scans, with tube voltages of 120 kV and 100 kV, respectively, and tube currents of 300~500 mA were automatically modulated, and the dose and flow rate of the contrast agent were fixed at 55 mL, 4.5 mL/s, saline with the same dose and flow rate for flushing and group C energy spectrum scanning, the tube voltage of the flat scanning group was 80 kV, the tube voltage of the enhancement group was 80~140 kV instantaneous switching, and the tube current was a constant 320 mA in all cases, with a personalized contrast agent injection scheme. The subjective evaluation, objective evaluation, and comparison of contrast use dose were performed on the imaging data of all groups. Results: The mean CT values of head and neck vessels in group B were greater than those in groups A and C, with statistically significant differences. At the aortic arch level, the SNR and CNR parameters in group B were better than those in groups A and C, with statistically significant differences. At the level of the remaining blood vessels, the SNR, CNR, and SD parameters of group C were better than those in groups A and B, excluding the common carotid artery level, with statistically significant differences. The radiation dose in group C was 53.9% and 27.6% lower than that in groups A and B, respectively, and the contrast dose was 27.2% lower. Conclusion: In middle-aged and elderly individuals, head and neck CTA with GSI scanning combined with “double-low” technique can effectively reduce radiation and contrast doses and improve image quality.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.15953/j.ctta.2024.072
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Value of GSI Scanning Combined with “Double-low” Technology in Head and Neck CTA in Middle-aged and Elderly Individuals

SHILAP Revista de lepidopterología
Advanced X-ray and CT Imaging
article

Analysis of the Value of GSI Scanning Combined with “Double-low” Technology in Head and Neck CTA in Middle-aged and Elderly Individuals

article en

Abstract

Objective: This study aimed to investigate the value of gemstone spectral imaging (GSI) scanning combined with "double-low" technology in head and neck computed tomography angiography (CTA) in middle-aged and elderly individuals. Materials and Methods: One hundred fifty patients who underwent head and neck CTA from February to December 2023 were retrospectively collected and divided into three groups, comprising 50 patients each, according to different scanning modalities; A, B, and C. Groups A and B underwent conventional spiral scans, with tube voltages of 120 kV and 100 kV, respectively, and tube currents of 300~500 mA were automatically modulated, and the dose and flow rate of the contrast agent were fixed at 55 mL, 4.5 mL/s, saline with the same dose and flow rate for flushing and group C energy spectrum scanning, the tube voltage of the flat scanning group was 80 kV, the tube voltage of the enhancement group was 80~140 kV instantaneous switching, and the tube current was a constant 320 mA in all cases, with a personalized contrast agent injection scheme. The subjective evaluation, objective evaluation, and comparison of contrast use dose were performed on the imaging data of all groups. Results: The mean CT values of head and neck vessels in group B were greater than those in groups A and C, with statistically significant differences. At the aortic arch level, the SNR and CNR parameters in group B were better than those in groups A and C, with statistically significant differences. At the level of the remaining blood vessels, the SNR, CNR, and SD parameters of group C were better than those in groups A and B, excluding the common carotid artery level, with statistically significant differences. The radiation dose in group C was 53.9% and 27.6% lower than that in groups A and B, respectively, and the contrast dose was 27.2% lower. Conclusion: In middle-aged and elderly individuals, head and neck CTA with GSI scanning combined with “double-low” technique can effectively reduce radiation and contrast doses and improve image quality.

SHILAP Revista de lepidopterología
University of Science and Technology of China (CN), Bengbu Medical College (CN)
Affordable and clean energy
Openalex Percentile: Top 54%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.