Vibratory and conventional impaction of acetabular components into porcine acetabula

Aims Sufficient primary implant stability with minimal bone damage is one of the challenges for uncemented implant fixation to prevent periprosthetic fractures and implant loosening. A pilot study on a non-viscoelastic material (polyurethane foam) showed a reduced impaction force when using vibratory implant insertion. This study assessed the effectiveness of vibratory implant insertion compared to an established implant insertion method in physiological viscoelastic bone from porcine hips. Methods Acetabular components were impacted line-to-line and into 1 mm nominal undersized cavities in porcine acetabula (n = 24 in total, n = 6 acetabula per group of study) using vibration (60 Hz) and 1 Hz (established) impaction methods. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods and different press-fits. Results The vibratory impaction method produced almost 40% lower impaction forces at both press-fit levels. However, complete seating at the nominal press-fit of 1 mm was not achieved, and primary stability was lower for the vibratory impaction for either press-fit. Conclusion Bone fracture risk due to high impaction forces could be reduced by vibrational implant insertion at the cost of a reduction in primary stability. The outcome of the vibratory impaction method in porcine bone was similar to a previous study using polyurethane foams, suggesting that the viscoelasticity of bone may not play a crucial role during press-fit implant impaction.

Publication Details

Journal
TUHH Open Research
Published
2025-04-01
DOI
https://doi.org/10.15480/882.15156
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vibratory and conventional impaction of acetabular components into porcine acetabula

TUHH Open Research
Orthopaedic implants and arthroplasty
article

Vibratory and conventional impaction of acetabular components into porcine acetabula

article en

Abstract

Aims Sufficient primary implant stability with minimal bone damage is one of the challenges for uncemented implant fixation to prevent periprosthetic fractures and implant loosening. A pilot study on a non-viscoelastic material (polyurethane foam) showed a reduced impaction force when using vibratory implant insertion. This study assessed the effectiveness of vibratory implant insertion compared to an established implant insertion method in physiological viscoelastic bone from porcine hips. Methods Acetabular components were impacted line-to-line and into 1 mm nominal undersized cavities in porcine acetabula (n = 24 in total, n = 6 acetabula per group of study) using vibration (60 Hz) and 1 Hz (established) impaction methods. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods and different press-fits. Results The vibratory impaction method produced almost 40% lower impaction forces at both press-fit levels. However, complete seating at the nominal press-fit of 1 mm was not achieved, and primary stability was lower for the vibratory impaction for either press-fit. Conclusion Bone fracture risk due to high impaction forces could be reduced by vibrational implant insertion at the cost of a reduction in primary stability. The outcome of the vibratory impaction method in porcine bone was similar to a previous study using polyurethane foams, suggesting that the viscoelasticity of bone may not play a crucial role during press-fit implant impaction.

TUHH Open Research
Openalex Percentile: Top 35%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.