Inductively Coupled Plasma-Mass Spectrometric Analysis of Mercury in Biological Samples and Interference Correction Methods

It is difficult to directly and accurately determine Hg in biological samples using inductively coupled plasma-mass spectrometry (ICP-MS) due to polyatomic interferences, such as tungsten oxide, and matrix effects. We established an ICP-MS method for the determination of Hg in biological samples based on the kinetic energy discrimination (KED) mode combined with mathematical correction and internal standard correction. In this experiment, spectral interferences of Hg in standard (STD) mode and KED mode were investigated. 202Hg was selected as the analyzed isotope in the KED mode, effectively reducing but not completely eliminating the interference. It was found that the interference amount of W with Hg was linearly related to the concentration of W (R2=0.9997). The matrix interference was eliminated with internal standard (Rh concentration of 50μg/L) and sample dilution (dilution of 100 times). The reliability of the method was tested with 9 reference materials, and the results were in agreement with certified values (or reference values). In particular, the accuracy of GBW10028 (Astragalus membranaceus), GBW10025 (spirulina) and GBW10015a (spinach) was significantly improved. The relative standard deviation (n=10) was 0.7% to 7.0%. The method is suitable for the analysis of Hg in biological samples.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-01-01
DOI
https://doi.org/10.15898/j.ykcs.202407020145
Primary Topic
Mercury impact and mitigation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inductively Coupled Plasma-Mass Spectrometric Analysis of Mercury in Biological Samples and Interference Correction Methods

SHILAP Revista de lepidopterología
Mercury impact and mitigation studies
article

Inductively Coupled Plasma-Mass Spectrometric Analysis of Mercury in Biological Samples and Interference Correction Methods

article en

Abstract

It is difficult to directly and accurately determine Hg in biological samples using inductively coupled plasma-mass spectrometry (ICP-MS) due to polyatomic interferences, such as tungsten oxide, and matrix effects. We established an ICP-MS method for the determination of Hg in biological samples based on the kinetic energy discrimination (KED) mode combined with mathematical correction and internal standard correction. In this experiment, spectral interferences of Hg in standard (STD) mode and KED mode were investigated. 202Hg was selected as the analyzed isotope in the KED mode, effectively reducing but not completely eliminating the interference. It was found that the interference amount of W with Hg was linearly related to the concentration of W (R2=0.9997). The matrix interference was eliminated with internal standard (Rh concentration of 50μg/L) and sample dilution (dilution of 100 times). The reliability of the method was tested with 9 reference materials, and the results were in agreement with certified values (or reference values). In particular, the accuracy of GBW10028 (Astragalus membranaceus), GBW10025 (spirulina) and GBW10015a (spinach) was significantly improved. The relative standard deviation (n=10) was 0.7% to 7.0%. The method is suitable for the analysis of Hg in biological samples.

SHILAP Revista de lepidopterología
Chinese Academy of Geological Sciences (CN)
Peace, Justice and strong institutions
Openalex Percentile: Top 45%
Mercury impact and mitigation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Inductively Coupled Plasma-Mass Spectrometric Analysis of Mercury in Biological Samples and Interference Correction Methods · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS