AC Fault Mechanism and Impact Analysis of Offshore Wind Power Connected to Flexible and Direct Systems

[Objective] In order to better understand the fault characteristics of offshore wind power access system, the impact analysis of AC fault characteristics of offshore wind power access system is carried out. [Method] The topology analysis of grid-connected transmission system of offshore wind power and the work control principle analysis of offshore wind power electrical structure were presented, including the work control principle analysis of PMSG, the topology and principle analysis of flexible and direct transmission system, the work control principle analysis of offshore converter station, the work control principle analysis of onshore converter station, and the work control principle analysis of offshore converter station. The fault characteristics and mechanism of offshore wind power access system were analyzed from two aspects: asymmetric fault and symmetric fault. [Result] The simulation model of PSCAD-based offshore wind power transmission through flexible direct transmission is established and verified. The correctness and universal applicability of the proposed mechanism analysis are verified through the simulation analysis of single-phase grounding fault and three-phase grounding fault. [Conclusion] The simulation results verify the correctness of the fault characteristic mechanism analysis. The symmetric component method can be satisfied with the fault analysis in the system with power electronic equipment access. In the case of asymmetric fault, the in-phase short-circuit current on both sides has a certain phase Angle difference, the negative sequence current on the soft straight side is the largest, and the short-circuit current on the wind side is generally small. There is only positive sequence current in the soft direct side and wind field side, and the phase of in-phase short-circuit current on both sides is almost the same, showing amplitude limitation.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-01-01
DOI
https://doi.org/10.16516/j.ceec.2023-268
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AC Fault Mechanism and Impact Analysis of Offshore Wind Power Connected to Flexible and Direct Systems

SHILAP Revista de lepidopterología
HVDC Systems and Fault Protection
article

AC Fault Mechanism and Impact Analysis of Offshore Wind Power Connected to Flexible and Direct Systems

article en

Abstract

[Objective] In order to better understand the fault characteristics of offshore wind power access system, the impact analysis of AC fault characteristics of offshore wind power access system is carried out. [Method] The topology analysis of grid-connected transmission system of offshore wind power and the work control principle analysis of offshore wind power electrical structure were presented, including the work control principle analysis of PMSG, the topology and principle analysis of flexible and direct transmission system, the work control principle analysis of offshore converter station, the work control principle analysis of onshore converter station, and the work control principle analysis of offshore converter station. The fault characteristics and mechanism of offshore wind power access system were analyzed from two aspects: asymmetric fault and symmetric fault. [Result] The simulation model of PSCAD-based offshore wind power transmission through flexible direct transmission is established and verified. The correctness and universal applicability of the proposed mechanism analysis are verified through the simulation analysis of single-phase grounding fault and three-phase grounding fault. [Conclusion] The simulation results verify the correctness of the fault characteristic mechanism analysis. The symmetric component method can be satisfied with the fault analysis in the system with power electronic equipment access. In the case of asymmetric fault, the in-phase short-circuit current on both sides has a certain phase Angle difference, the negative sequence current on the soft straight side is the largest, and the short-circuit current on the wind side is generally small. There is only positive sequence current in the soft direct side and wind field side, and the phase of in-phase short-circuit current on both sides is almost the same, showing amplitude limitation.

SHILAP Revista de lepidopterología
Shenzhen Stock Exchange (CN), Guangdong Hydropower Planning & Design Institute (CN), China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 54%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.