Effect Analysis of Track Vibration Reduction Measures on Viaduct Environmental Vibration Induced by Vehicle Operation

[Objective]When a train running on the viaduct track, the rail vibration caused by the vehicle-track interaction will be transmitted to the bridge, piers, and pile foundations through the track structure, thereby triggering ground vibration around the bridge. Therefore, it is necessary to study the impact of elevated section rail and track bed vibration reduction on the environment for elevated rail transit. [Method]Based on the vehicle-track multi-body dynamics theory and the finite element method, a vehicle-track-U beam bridge-soil vibration model is established to solve the vibration response of the ground source intensity near the viaduct when rail transit veh-icles passing through. [Result & Conclusion]The peak frequency band of the ground source intensity vertical vibration frequency for elevated section is distributed in 40 ~ 60 Hz. Vibration-damping fasteners, trapezoidal sleepers, vibration-damping pad floating plates and steel spring floating plates all have a reduction effect on the ground source intensity vibration, and their contribution is mainly reflected in the vibration frequency range of 25 ~ 100 Hz. Under the conditions of using vibration-damping fasteners, trapezoidal sleepers, vibration-damping pad floating plates, and steel spring floating plates, when the vibration frequency is 40 ~ 50 Hz, the ground source intensity vibration acceleration levels are reduced by about 4.2 ~ 4.4 dB, 6.5 ~ 6.9 dB, 7.8 ~ 8.1 dB and 10.0~10.7 dB respectively. When the fastener stiffness is ≤15 kN/mm, the rail vertical displacement and vertical acceleration peak value increase significantly. When the fastener stiffness decreases from 60 kN/mm to 10 kN/mm, the rail vertical displacement and acceleration peak value increase by about 5 times and 18.26% respectively. In the peak frequency band of 40 ~ 50 Hz, the vertical vibration acceleration level at the ground source intensity decreases by about 4.5 ~ 4.9 dB.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.16037/j.1007-869x.2024.12.013
Primary Topic
Railway Engineering and Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect Analysis of Track Vibration Reduction Measures on Viaduct Environmental Vibration Induced by Vehicle Operation

SHILAP Revista de lepidopterología
Railway Engineering and Dynamics
article

Effect Analysis of Track Vibration Reduction Measures on Viaduct Environmental Vibration Induced by Vehicle Operation

article en

Abstract

[Objective]When a train running on the viaduct track, the rail vibration caused by the vehicle-track interaction will be transmitted to the bridge, piers, and pile foundations through the track structure, thereby triggering ground vibration around the bridge. Therefore, it is necessary to study the impact of elevated section rail and track bed vibration reduction on the environment for elevated rail transit. [Method]Based on the vehicle-track multi-body dynamics theory and the finite element method, a vehicle-track-U beam bridge-soil vibration model is established to solve the vibration response of the ground source intensity near the viaduct when rail transit veh-icles passing through. [Result & Conclusion]The peak frequency band of the ground source intensity vertical vibration frequency for elevated section is distributed in 40 ~ 60 Hz. Vibration-damping fasteners, trapezoidal sleepers, vibration-damping pad floating plates and steel spring floating plates all have a reduction effect on the ground source intensity vibration, and their contribution is mainly reflected in the vibration frequency range of 25 ~ 100 Hz. Under the conditions of using vibration-damping fasteners, trapezoidal sleepers, vibration-damping pad floating plates, and steel spring floating plates, when the vibration frequency is 40 ~ 50 Hz, the ground source intensity vibration acceleration levels are reduced by about 4.2 ~ 4.4 dB, 6.5 ~ 6.9 dB, 7.8 ~ 8.1 dB and 10.0~10.7 dB respectively. When the fastener stiffness is ≤15 kN/mm, the rail vertical displacement and vertical acceleration peak value increase significantly. When the fastener stiffness decreases from 60 kN/mm to 10 kN/mm, the rail vertical displacement and acceleration peak value increase by about 5 times and 18.26% respectively. In the peak frequency band of 40 ~ 50 Hz, the vertical vibration acceleration level at the ground source intensity decreases by about 4.5 ~ 4.9 dB.

SHILAP Revista de lepidopterología
Haier Group (China) (CN), Guangzhou Metro Group (China) (CN), Qingdao Center of Resource Chemistry and New Materials (CN)
Life in Land
Openalex Percentile: Top 64%
Railway Engineering and Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.