Validation of Noninvasive Assessment of Pulmonary Gas Exchange in Patients with Chronic Obstructive Pulmonary Disease during Initial Exposure to High Altitude

Investigation of pulmonary gas exchange efficacy usually requires arterial blood gas analysis (aBGA) to determine arterial partial pressure of oxygen (mPaO₂) and compute the Riley alveolar-to-arterial oxygen difference (A-aDO₂); that is a demanding and invasive procedure. A noninvasive approach (AGM100), allowing the calculation of PaO₂ (cPaO₂) derived from pulse oximetry (SpO₂), has been developed, but this has not been validated in a large cohort of chronic obstructive pulmonary disease (COPD) patients. Our aim was to conduct a validation study of the AG100 in hypoxemic moderate-to-severe COPD. Concurrent measurements of cPaO₂ (AGM100) and mPaO₂ (EPOC, portable aBGA device) were performed in 131 moderate-to-severe COPD patients (mean ±SD FEV₁: 60 ± 10% of predicted value) and low-altitude residents, becoming hypoxemic (i.e., SpO₂ < 94%) during a short stay at 3100 m (Too-Ashu, Kyrgyzstan). Agreements between cPaO₂ (AGM100) and mPaO₂ (EPOC) and between the O₂-deficit (calculated as the difference between end-tidal pressure of O₂ and cPaO₂ by the AGM100) and Riley A-aDO₂ were assessed. Mean bias (±SD) between cPaO₂ and mPaO₂ was 2.0 ± 4.6 mmHg (95% Confidence Interval (CI): 1.2 to 2.8 mmHg) with 95% limits of agreement (LoA): −7.1 to 11.1 mmHg. In multivariable analysis, larger body mass index (p = 0.046), an increase in SpO₂ (p < 0.001), and an increase in PaCO₂-PETCO₂ difference (p < 0.001) were associated with imprecision (i.e., the discrepancy between cPaO₂ and mPaO₂). The positive predictive value of cPaO₂ to detect severe hypoxemia (i.e., PaO₂ ≤ 55 mmHg) was 0.94 (95% CI: 0.87 to 0.98) with a positive likelihood ratio of 3.77 (95% CI: 1.71 to 8.33). The mean bias between O₂-deficit and A-aDO₂ was 6.2 ± 5.5 mmHg (95% CI: 5.3 to 7.2 mmHg; 95%LoA: −4.5 to 17.0 mmHg). AGM100 provided an accurate estimate of PaO₂ in hypoxemic patients with COPD, but the precision for individual values was modest. This device is promising for noninvasive assessment of pulmonary gas exchange efficacy in COPD patients.

Publication Details

Journal
Open Collections
Published
2025-01-01
DOI
https://doi.org/10.14288/1.0448050
Primary Topic
Rice Cultivation and Yield Improvement
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of Noninvasive Assessment of Pulmonary Gas Exchange in Patients with Chronic Obstructive Pulmonary Disease during Initial Exposure to High Altitude

Open Collections
Rice Cultivation and Yield Improvement
article

Validation of Noninvasive Assessment of Pulmonary Gas Exchange in Patients with Chronic Obstructive Pulmonary Disease during Initial Exposure to High Altitude

article en

Abstract

Investigation of pulmonary gas exchange efficacy usually requires arterial blood gas analysis (aBGA) to determine arterial partial pressure of oxygen (mPaO₂) and compute the Riley alveolar-to-arterial oxygen difference (A-aDO₂); that is a demanding and invasive procedure. A noninvasive approach (AGM100), allowing the calculation of PaO₂ (cPaO₂) derived from pulse oximetry (SpO₂), has been developed, but this has not been validated in a large cohort of chronic obstructive pulmonary disease (COPD) patients. Our aim was to conduct a validation study of the AG100 in hypoxemic moderate-to-severe COPD. Concurrent measurements of cPaO₂ (AGM100) and mPaO₂ (EPOC, portable aBGA device) were performed in 131 moderate-to-severe COPD patients (mean ±SD FEV₁: 60 ± 10% of predicted value) and low-altitude residents, becoming hypoxemic (i.e., SpO₂ < 94%) during a short stay at 3100 m (Too-Ashu, Kyrgyzstan). Agreements between cPaO₂ (AGM100) and mPaO₂ (EPOC) and between the O₂-deficit (calculated as the difference between end-tidal pressure of O₂ and cPaO₂ by the AGM100) and Riley A-aDO₂ were assessed. Mean bias (±SD) between cPaO₂ and mPaO₂ was 2.0 ± 4.6 mmHg (95% Confidence Interval (CI): 1.2 to 2.8 mmHg) with 95% limits of agreement (LoA): −7.1 to 11.1 mmHg. In multivariable analysis, larger body mass index (p = 0.046), an increase in SpO₂ (p < 0.001), and an increase in PaCO₂-PETCO₂ difference (p < 0.001) were associated with imprecision (i.e., the discrepancy between cPaO₂ and mPaO₂). The positive predictive value of cPaO₂ to detect severe hypoxemia (i.e., PaO₂ ≤ 55 mmHg) was 0.94 (95% CI: 0.87 to 0.98) with a positive likelihood ratio of 3.77 (95% CI: 1.71 to 8.33). The mean bias between O₂-deficit and A-aDO₂ was 6.2 ± 5.5 mmHg (95% CI: 5.3 to 7.2 mmHg; 95%LoA: −4.5 to 17.0 mmHg). AGM100 provided an accurate estimate of PaO₂ in hypoxemic patients with COPD, but the precision for individual values was modest. This device is promising for noninvasive assessment of pulmonary gas exchange efficacy in COPD patients.

Open Collections
Good health and well-being
Openalex Percentile: Top 37%
Rice Cultivation and Yield Improvement
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validation of Noninvasive Assessment of Pulmonary Gas Exchange in Patients with Chronic Obstructive Pulmonary Disease during Initial Exposure to High Altitude · Open Collections (2025) | TGRS Research Map | TGRS