Experimental study on the effect of spray evaporative condensation on air conditioning performance

In order to reduce the energy consumption of air conditioning units in high-temperature working conditions and improve the energy efficiency ratio of the units, this study proposes to apply the spray evaporative condensation technology to air conditioning condensers. Firstly, the water flow required for spraying was theoretically calculated, and the nozzles were used to cool the V-type condenser of air conditioner; then, in the standard enthalpy difference laboratory, the relevant experimernts of different distances between the nozzles and the condenser, different injection angles and intermittent spray were carried out, and the energy-saving effect of spray under different working conditions were analyzed. The results show that the spray evaporation condensation technology applied to the condenser has a better energy-saving effect. The optimal installation distance between the nozzle and condenser is 40 cm, the optimal spray angle of the nozzle is 60°, in the indoor dry bulb temperature of 37 ℃, outdoor dry/wet bulb temperature of 35/27 ℃, the energy efficiency ratio of the unit increases from 4.0 to 4.89, the energy efficiency improvement rate is 22.2%, and the energy efficiency improvement rate decreases with the drop of the outdoor temperature. The technology is more suitable for high-temperature areas. It can provide a reference for the application of the technology in air conditioner condenser.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.13338/j.issn.1674-649x.2024.05.014
Primary Topic
Diverse Scientific and Economic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on the effect of spray evaporative condensation on air conditioning performance

SHILAP Revista de lepidopterología
Diverse Scientific and Economic Studies
article

Experimental study on the effect of spray evaporative condensation on air conditioning performance

article en

Abstract

In order to reduce the energy consumption of air conditioning units in high-temperature working conditions and improve the energy efficiency ratio of the units, this study proposes to apply the spray evaporative condensation technology to air conditioning condensers. Firstly, the water flow required for spraying was theoretically calculated, and the nozzles were used to cool the V-type condenser of air conditioner; then, in the standard enthalpy difference laboratory, the relevant experimernts of different distances between the nozzles and the condenser, different injection angles and intermittent spray were carried out, and the energy-saving effect of spray under different working conditions were analyzed. The results show that the spray evaporation condensation technology applied to the condenser has a better energy-saving effect. The optimal installation distance between the nozzle and condenser is 40 cm, the optimal spray angle of the nozzle is 60°, in the indoor dry bulb temperature of 37 ℃, outdoor dry/wet bulb temperature of 35/27 ℃, the energy efficiency ratio of the unit increases from 4.0 to 4.89, the energy efficiency improvement rate is 22.2%, and the energy efficiency improvement rate decreases with the drop of the outdoor temperature. The technology is more suitable for high-temperature areas. It can provide a reference for the application of the technology in air conditioner condenser.

SHILAP Revista de lepidopterología
Xi'an Polytechnic University (CN), Midea Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 39%
Diverse Scientific and Economic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental study on the effect of spray evaporative condensation on air conditioning performance · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS