Evaluation of Weakening Effect of Stator Parallel Branch Circuit on Main Field Asymmetry

The short circuit between turns of the rotor winding is a weak characteristic electrical fault of the turbine generator, which makes the fault detection difficult. This paper investigates the weakening effect of the circulating magnetic field inside the parallel branch of the stator winding of a turbine generator on the asymmetric magnetic field generated by the rotor winding turn-to-turn short-circuit, derives the expression of the excitation magnetic field under the fault condition, obtains the expression of the circulating current of the parallel branch of the stator winding and the expression of the magnetic field generated by the circulating current, and finds out the offsetting effect of the circulating field on the original asymmetric magnetic field. A 300MW steam turbine generator is used as an example to carry out finite element simulation, which proves the weakening effect of the parallel branch structure of the stator winding on the short-circuit fault characteristics of the rotor winding, and the research conclusion is helpful to analyze the external appearance and causes of the short-circuit fault characteristics between turns of the rotor winding, and also provides theoretical support for the feature extraction in the fault diagnosis stage.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.11930/j.issn.1004-9649.202404088
Primary Topic
Plant Pathogens and Resistance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Weakening Effect of Stator Parallel Branch Circuit on Main Field Asymmetry

SHILAP Revista de lepidopterología
Plant Pathogens and Resistance
article

Evaluation of Weakening Effect of Stator Parallel Branch Circuit on Main Field Asymmetry

article en

Abstract

The short circuit between turns of the rotor winding is a weak characteristic electrical fault of the turbine generator, which makes the fault detection difficult. This paper investigates the weakening effect of the circulating magnetic field inside the parallel branch of the stator winding of a turbine generator on the asymmetric magnetic field generated by the rotor winding turn-to-turn short-circuit, derives the expression of the excitation magnetic field under the fault condition, obtains the expression of the circulating current of the parallel branch of the stator winding and the expression of the magnetic field generated by the circulating current, and finds out the offsetting effect of the circulating field on the original asymmetric magnetic field. A 300MW steam turbine generator is used as an example to carry out finite element simulation, which proves the weakening effect of the parallel branch structure of the stator winding on the short-circuit fault characteristics of the rotor winding, and the research conclusion is helpful to analyze the external appearance and causes of the short-circuit fault characteristics between turns of the rotor winding, and also provides theoretical support for the feature extraction in the fault diagnosis stage.

SHILAP Revista de lepidopterología
North China Electric Power University (CN)
Affordable and clean energy
Openalex Percentile: Top 40%
Plant Pathogens and Resistance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.