Performance of the 0-padding Optimal Filter Method in Non-linear Gain Calibration

The focal-plane detector, the X-ray Integral Field Unit (X-IFU), on-board ESA's Athena space telescope is a transition edge sensor (TES) microcalorimeter array with 1.5k pixels, designed to provide spatially-resolved, high-resolution spectroscopy over the energy range 0.2-12 keV. The onboard event processor uses a digital optimal filter to determine the pulse-height of the measured current pulse from every X-ray photon striking the array. A modified optimal filter called the 0-padding filter has recently been proposed. This is a truncated version of the standard optimal filter and has been shown to provide comparable energy resolution but with the benefit of reduced computational expense. Whereas the standard optimal filter has zero integral and is not sensitive to variations in the DC level of the measured signal, the integral of the 0-padded version is non-zero and thus is more sensitive to fluctuations in DC signal over time. In this work, we explore the effect of 0-padding on the energy scale calibration using data from 250-pixels in a prototype Athena X-IFU array, measured over the range 1.3-12 keV.

Publication Details

Journal
Maryland Shared Open Access Repository (USMAI Consortium)
Published
2025-01-22
DOI
https://doi.org/10.13016/m292af-pxoh
Primary Topic
Wheat and Barley Genetics and Pathology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of the 0-padding Optimal Filter Method in Non-linear Gain Calibration

Maryland Shared Open Access Repository (USMAI Consortium)
Wheat and Barley Genetics and Pathology
article

Performance of the 0-padding Optimal Filter Method in Non-linear Gain Calibration

article en

Abstract

The focal-plane detector, the X-ray Integral Field Unit (X-IFU), on-board ESA's Athena space telescope is a transition edge sensor (TES) microcalorimeter array with 1.5k pixels, designed to provide spatially-resolved, high-resolution spectroscopy over the energy range 0.2-12 keV. The onboard event processor uses a digital optimal filter to determine the pulse-height of the measured current pulse from every X-ray photon striking the array. A modified optimal filter called the 0-padding filter has recently been proposed. This is a truncated version of the standard optimal filter and has been shown to provide comparable energy resolution but with the benefit of reduced computational expense. Whereas the standard optimal filter has zero integral and is not sensitive to variations in the DC level of the measured signal, the integral of the 0-padded version is non-zero and thus is more sensitive to fluctuations in DC signal over time. In this work, we explore the effect of 0-padding on the energy scale calibration using data from 250-pixels in a prototype Athena X-IFU array, measured over the range 1.3-12 keV.

Maryland Shared Open Access Repository (USMAI Consortium)
National Aeronautics and Space Administration, Goddard Space Flight Center, European Regional Development Fund, Agencia Estatal de Investigación
Affordable and clean energy
Openalex Percentile: Top 40%
Wheat and Barley Genetics and Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance of the 0-padding Optimal Filter Method in Non-linear Gain Calibration · Maryland Shared Open Access Repository (USMAI Consortium) (2025) | TGRS Research Map | TGRS