Design of a water heating system for automatic coffee maker using OMRON CP1E-NA20DR-A PLC and PID control

Various human activities require alternatives to replace activities such as making coffee drinks by providing automatic coffee drink makers. Automatic coffee makers require an accurate water heating system, while the water used to brew coffee drinks is not less than 80ºC and not more than 85ºC. This research designs a water heating system using an LM35DZ sensor as a temperature reader, an Omron-NA20DR-A PLC as a processor, and a heating tube used to heat water. PID algorithm is used to control the water temperature. The results of this study show that controlling water temperature using the PID algorithm with the Omron CP1E-NA20DR-A PLC can work well. The results of controlling the water temperature at a set point of 82ºC the system works with the parameter values Proportional Band = 20%, Integral Time = 50 seconds, and Derivative Time = 0.2 seconds resulting in a system response with a rise time value = 267 seconds, overshoot = 2.19 ºC, and peak time = 360 seconds.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-01-09
DOI
https://doi.org/10.1051/bioconf/202414802021/pdf
Primary Topic
Pasture and Agricultural Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a water heating system for automatic coffee maker using OMRON CP1E-NA20DR-A PLC and PID control

Springer Link (Chiba Institute of Technology)
Pasture and Agricultural Systems
article

Design of a water heating system for automatic coffee maker using OMRON CP1E-NA20DR-A PLC and PID control

article en

Abstract

Various human activities require alternatives to replace activities such as making coffee drinks by providing automatic coffee drink makers. Automatic coffee makers require an accurate water heating system, while the water used to brew coffee drinks is not less than 80ºC and not more than 85ºC. This research designs a water heating system using an LM35DZ sensor as a temperature reader, an Omron-NA20DR-A PLC as a processor, and a heating tube used to heat water. PID algorithm is used to control the water temperature. The results of this study show that controlling water temperature using the PID algorithm with the Omron CP1E-NA20DR-A PLC can work well. The results of controlling the water temperature at a set point of 82ºC the system works with the parameter values Proportional Band = 20%, Integral Time = 50 seconds, and Derivative Time = 0.2 seconds resulting in a system response with a rise time value = 267 seconds, overshoot = 2.19 ºC, and peak time = 360 seconds.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 44%
Pasture and Agricultural Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.