Structural Alteration and Electric Field Estimation Inside HVAC Cable due to Inhomogeneous Aging

Under diverse loading conditions, high-voltage alternating current (HV-AC) underground polymeric cables exhibit a radial temperature gradient and experience differential thermal stress, resulting in inhomogeneous aging of the polymeric material. Consequently, a differential localized structural alterations occur at different radial positions within the insulation bulk of the cable. To investigate these effects, the authors have examined the cross-linked polyethylene (XLPE) insulation taken from HV-AC cables. Using a lathe machine, samples were extracted and subjected to various tests. The findings revealed significant variations in the morphology of the XLPE layers at different radial positions within the cable insulation bulk. These effects were further investigated by measuring the permittivity of samples extracted from different radial positions within the insulation bulk. The permittivity data is then fitted to field, temperature and radial position dependent equation, and the AC electric field distribution is estimated. The findings are also corroborated by AC breakdown tests.

Institutions

Publication Details

Published
2024-10-06
DOI
https://doi.org/10.1109/ceidp61745.2024.10907555
Primary Topic
Agricultural Practices and Plant Genetics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural Alteration and Electric Field Estimation Inside HVAC Cable due to Inhomogeneous Aging

Agricultural Practices and Plant Genetics
article

Structural Alteration and Electric Field Estimation Inside HVAC Cable due to Inhomogeneous Aging

article en

Abstract

Under diverse loading conditions, high-voltage alternating current (HV-AC) underground polymeric cables exhibit a radial temperature gradient and experience differential thermal stress, resulting in inhomogeneous aging of the polymeric material. Consequently, a differential localized structural alterations occur at different radial positions within the insulation bulk of the cable. To investigate these effects, the authors have examined the cross-linked polyethylene (XLPE) insulation taken from HV-AC cables. Using a lathe machine, samples were extracted and subjected to various tests. The findings revealed significant variations in the morphology of the XLPE layers at different radial positions within the cable insulation bulk. These effects were further investigated by measuring the permittivity of samples extracted from different radial positions within the insulation bulk. The permittivity data is then fitted to field, temperature and radial position dependent equation, and the AC electric field distribution is estimated. The findings are also corroborated by AC breakdown tests.

Indian Institute of Technology Ropar (IN)
Affordable and clean energy
Openalex Percentile: Top 39%
Agricultural Practices and Plant Genetics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Structural Alteration and Electric Field Estimation Inside HVAC Cable due to Inhomogeneous Aging · (2024) | TGRS Research Map | TGRS