A Calibration Strategy\nfor Silicon Nanowire Field-Effect\nTransistor Biosensors and Its Application in Ultra-Sensitive, Label-Free\nBiosensing

The silicon nanowire field-effect transistor (SiNW FET)\nhas been\ndeveloped for over two decades as an ultrasensitive, label-free biosensor\nfor biodetection. However, inconsistencies in manufacturing and surface\nfunctionalization at the nanoscale have led to poor sensor-to-sensor\nconsistency in performance. Despite extensive efforts to address this\nissue through process improvements and calibration methods, the outcomes\nhave not been satisfactory. Herein, based on the strong correlation\nbetween the saturation response of SiNW FET biosensors and both their\nfeature size and surface functionalization, we propose a calibration\nstrategy that combines the sensing principles of SiNW FET with the\nLangmuir–Freundlich model. By normalizing the response of the\nSiNW FET biosensors (Δ<i>I</i>/<i>I</i><sub>0</sub>) with their saturation response (Δ<i>I</i>/<i>I</i><sub>0</sub>)<sub>max</sub>, this strategy fundamentally\novercomes the issues mentioned above. It has enabled label-free detection\nof nucleic acids, proteins, and exosomes within 5 min, achieving detection\nlimits as low as attomoles and demonstrating a significant reduction\nin the coefficient of variation. Notably, the nucleic acid test results\nexhibit a strong correlation with the ultraviolet–visible (UV–vis)\nspectrophotometer measurements, with a correlation coefficient reaching\n0.933. The proposed saturation response calibration strategy exhibits\ngood universality and practicability in biological detection applications,\nproviding theoretical and experimental support for the transition\nof mass-manufactured nanosensors from theoretical research to practical\napplication.

Publication Details

Journal
Figshare
Published
2024-08-08
DOI
https://doi.org/10.1021/acsnano.4c01937.s001
Primary Topic
Nanowire Synthesis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Calibration Strategy\nfor Silicon Nanowire Field-Effect\nTransistor Biosensors and Its Application in Ultra-Sensitive, Label-Free\nBiosensing

Figshare
Nanowire Synthesis and Applications
article

A Calibration Strategy\nfor Silicon Nanowire Field-Effect\nTransistor Biosensors and Its Application in Ultra-Sensitive, Label-Free\nBiosensing

article en

Abstract

The silicon nanowire field-effect transistor (SiNW FET)\nhas been\ndeveloped for over two decades as an ultrasensitive, label-free biosensor\nfor biodetection. However, inconsistencies in manufacturing and surface\nfunctionalization at the nanoscale have led to poor sensor-to-sensor\nconsistency in performance. Despite extensive efforts to address this\nissue through process improvements and calibration methods, the outcomes\nhave not been satisfactory. Herein, based on the strong correlation\nbetween the saturation response of SiNW FET biosensors and both their\nfeature size and surface functionalization, we propose a calibration\nstrategy that combines the sensing principles of SiNW FET with the\nLangmuir–Freundlich model. By normalizing the response of the\nSiNW FET biosensors (Δ<i>I</i>/<i>I</i><sub>0</sub>) with their saturation response (Δ<i>I</i>/<i>I</i><sub>0</sub>)<sub>max</sub>, this strategy fundamentally\novercomes the issues mentioned above. It has enabled label-free detection\nof nucleic acids, proteins, and exosomes within 5 min, achieving detection\nlimits as low as attomoles and demonstrating a significant reduction\nin the coefficient of variation. Notably, the nucleic acid test results\nexhibit a strong correlation with the ultraviolet–visible (UV–vis)\nspectrophotometer measurements, with a correlation coefficient reaching\n0.933. The proposed saturation response calibration strategy exhibits\ngood universality and practicability in biological detection applications,\nproviding theoretical and experimental support for the transition\nof mass-manufactured nanosensors from theoretical research to practical\napplication.

Figshare
Openalex Percentile: Top 65%
Nanowire Synthesis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.