Self-Healing Engineered Multilayer Coatings for CorrosionProtection of Magnesium Alloy AZ31B

Nonporous, crack-free hybrid glass coatings have provided excellent corrosion protection to the AZ31B magnesium alloy. However, if a crack develops in the coatings, then corrosion will proliferate at that point. The novelty of this study consists of engineering a bilayer protection system that combines the “barrier” properties of the hybrid glass coatings with the “inhibitor” or “self-healing” effect of an internal layer of mesoporous silica doped with cerium(III) ions. The mesoporous layer was obtained using a sol–gel solution with 1 mol % cerium(III) ions. The inner cerium-doped mesoporous coating has a thickness of 0.25 μm, and the electrochemical characterization through Open circuit potential (OCP) and Electrochemical Impedance Spectroscopy (EIS) indicates a corrosion inhibition process provided by cerium(III) ions triggered by the corrosion. The combination of the Ce-doped and hybrid glass coatings reaches a total thickness of 5.1 μm. The corrosion evaluation through OCP and EIS does not show any evidence of corrosion during the first 575 h of immersion. After this, there are several steps of a sudden drop in potential and subsequent recovery of the previous values, which could be associated with the activation of the corrosion inhibition mechanism provided by the Ce (III) ions. EIS show a maximum impedance module of 10<sup>6.7</sup> Ohm cm<sup>2</sup>, a decrease of impedance values and phase angle fluctuations after the potential drops observed, and, then, a recovery of the previous values of impedance and phase angle. This behavior confirms activation of the corrosion inhibition mechanism. Polarization curves shows that the multilayer coating leads to a low current density (∼10<sup>–11</sup> A cm<sup>–2</sup>), around 5 orders of magnitude lower in comparison with the bare substrate. A <i>post-mortem</i> SEM-EDX analysis study, performed on the cracks generated during electrochemical testing, shows the accumulation of cerium as a consequence of the corrosion inhibitory process.

Publication Details

Journal
Figshare
Published
2025-01-28
DOI
https://doi.org/10.1021/acsmaterialsau.4c00170.s001
Primary Topic
Plant Pathogens and Resistance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Healing Engineered Multilayer Coatings for CorrosionProtection of Magnesium Alloy AZ31B

Figshare
Plant Pathogens and Resistance
article

Self-Healing Engineered Multilayer Coatings for CorrosionProtection of Magnesium Alloy AZ31B

article en

Abstract

Nonporous, crack-free hybrid glass coatings have provided excellent corrosion protection to the AZ31B magnesium alloy. However, if a crack develops in the coatings, then corrosion will proliferate at that point. The novelty of this study consists of engineering a bilayer protection system that combines the “barrier” properties of the hybrid glass coatings with the “inhibitor” or “self-healing” effect of an internal layer of mesoporous silica doped with cerium(III) ions. The mesoporous layer was obtained using a sol–gel solution with 1 mol % cerium(III) ions. The inner cerium-doped mesoporous coating has a thickness of 0.25 μm, and the electrochemical characterization through Open circuit potential (OCP) and Electrochemical Impedance Spectroscopy (EIS) indicates a corrosion inhibition process provided by cerium(III) ions triggered by the corrosion. The combination of the Ce-doped and hybrid glass coatings reaches a total thickness of 5.1 μm. The corrosion evaluation through OCP and EIS does not show any evidence of corrosion during the first 575 h of immersion. After this, there are several steps of a sudden drop in potential and subsequent recovery of the previous values, which could be associated with the activation of the corrosion inhibition mechanism provided by the Ce (III) ions. EIS show a maximum impedance module of 10<sup>6.7</sup> Ohm cm<sup>2</sup>, a decrease of impedance values and phase angle fluctuations after the potential drops observed, and, then, a recovery of the previous values of impedance and phase angle. This behavior confirms activation of the corrosion inhibition mechanism. Polarization curves shows that the multilayer coating leads to a low current density (∼10<sup>–11</sup> A cm<sup>–2</sup>), around 5 orders of magnitude lower in comparison with the bare substrate. A <i>post-mortem</i> SEM-EDX analysis study, performed on the cracks generated during electrochemical testing, shows the accumulation of cerium as a consequence of the corrosion inhibitory process.

Figshare
Openalex Percentile: Top 41%
Plant Pathogens and Resistance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.