Enhanced Detectionof Enrofloxacin in Seawater Usinga Newly Selected Aptamer on a Graphite Oxide-Based Biosensor

Developing aptasensors offers several advantages including sensitivity, selectivity, cost-effectiveness, and speed over traditional analytical techniques for antibiotic detection. We have successfully identified Enro_ap3, a 30-mer enrofloxacin-binding aptamer with micromolar binding affinity, through an optimized Capture-SELEX platform. Compared to other reported enrofloxacin-binding aptamers, this shorter aptamer not only streamlines the design process but also eliminates the common issue of strong nonspecific binding to the GO surface, thereby improving the overall detection capabilities of the biosensor (GO-Enro_ap3-FAM). This GO aptasensor demonstrated remarkable selectivity by effectively distinguishing enrofloxacin from different structurally diverse antibiotics. The sensor boasts a LOD of 32.15 μg/mL, 2.5 times more sensitive than the original 30-mer, with recoveries of 74%–92% and relative standard deviations of 6.3%–12.5% in seawater samples spiked with enrofloxacin. Furthermore, the GO aptasensor’s detection capabilities were found to be on par with traditional LC-MS/MS techniques, exhibiting no significant differences in recovery rates even in complex matrices. The sensor’s performance remained consistent across variations in salinity, acidity, and total organic carbon concentrations in seawater samples collected from different locations, underlining its robustness in diverse environmental conditions and its suitability for real-world seawater monitoring applications. Our findings highlight the importance of the aptamer’s chain length and its binding affinity toward the target after immobilization on the GO substrate. These factors significantly impact the performance of GO aptasensors in seawater. Overall, the GO aptasensor provides a well-balanced approach, combining sensitivity, environmental adaptability, and practical usability for detecting pharmaceutical contaminants, such as antibiotics, in marine environments.

Publication Details

Journal
Figshare
Published
2025-03-24
DOI
https://doi.org/10.1021/acs.analchem.4c07052.s001
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Detectionof Enrofloxacin in Seawater Usinga Newly Selected Aptamer on a Graphite Oxide-Based Biosensor

Figshare
Advanced biosensing and bioanalysis techniques
article

Enhanced Detectionof Enrofloxacin in Seawater Usinga Newly Selected Aptamer on a Graphite Oxide-Based Biosensor

article en

Abstract

Developing aptasensors offers several advantages including sensitivity, selectivity, cost-effectiveness, and speed over traditional analytical techniques for antibiotic detection. We have successfully identified Enro_ap3, a 30-mer enrofloxacin-binding aptamer with micromolar binding affinity, through an optimized Capture-SELEX platform. Compared to other reported enrofloxacin-binding aptamers, this shorter aptamer not only streamlines the design process but also eliminates the common issue of strong nonspecific binding to the GO surface, thereby improving the overall detection capabilities of the biosensor (GO-Enro_ap3-FAM). This GO aptasensor demonstrated remarkable selectivity by effectively distinguishing enrofloxacin from different structurally diverse antibiotics. The sensor boasts a LOD of 32.15 μg/mL, 2.5 times more sensitive than the original 30-mer, with recoveries of 74%–92% and relative standard deviations of 6.3%–12.5% in seawater samples spiked with enrofloxacin. Furthermore, the GO aptasensor’s detection capabilities were found to be on par with traditional LC-MS/MS techniques, exhibiting no significant differences in recovery rates even in complex matrices. The sensor’s performance remained consistent across variations in salinity, acidity, and total organic carbon concentrations in seawater samples collected from different locations, underlining its robustness in diverse environmental conditions and its suitability for real-world seawater monitoring applications. Our findings highlight the importance of the aptamer’s chain length and its binding affinity toward the target after immobilization on the GO substrate. These factors significantly impact the performance of GO aptasensors in seawater. Overall, the GO aptasensor provides a well-balanced approach, combining sensitivity, environmental adaptability, and practical usability for detecting pharmaceutical contaminants, such as antibiotics, in marine environments.

Figshare
Life below water
Openalex Percentile: Top 53%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.