MinimizingSensor-Sample Distances in Scanning Nitrogen-VacancyMagnetometry

Scanning magnetometry with nitrogen-vacancy (NV) centers in diamond has led to significant advances in the sensitive imaging of magnetic systems. The spatial resolution of the technique, however, remains limited to tens to hundreds of nanometers, even for probes where NV centers are engineered within 10 nm from the tip apex. Here, we present a correlated investigation of the crucial parameters that determine the spatial resolution: the mechanical and magnetic stand-off distances, as well as the subsurface NV center depth in diamond. We study their contributions using mechanical approach curves, photoluminescence measurements, magnetometry scans, and nuclear magnetic resonance (NMR) spectroscopy of surface adsorbates. We first show that the stand-off distance is mainly limited by features on the surface of the diamond tip, hindering mechanical access. Next, we demonstrate that frequency-modulated (FM) atomic force microscopy feedback partially overcomes this issue, leading to closer and more consistent magnetic stand-off distances (26–87 nm) compared with the more common amplitude-modulated feedback (43–128 nm). FM operation thus permits improved magnetic imaging of sub-100-nm spin textures, shown for the spin cycloid in BiFeO<sub>3</sub> and domain walls in a CoFeB synthetic antiferromagnet. Finally, by examining <sup>1</sup>H and <sup>19</sup>F NMR signals in soft contact with a polytetrafluoroethylene surface, we demonstrate a minimum NV-to-sample distance of 7.9 ± 0.4 nm.

Publication Details

Journal
Figshare
Published
2025-02-21
DOI
https://doi.org/10.1021/acsnano.4c18460.s001
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MinimizingSensor-Sample Distances in Scanning Nitrogen-VacancyMagnetometry

Figshare
Diamond and Carbon-based Materials Research
article

MinimizingSensor-Sample Distances in Scanning Nitrogen-VacancyMagnetometry

article en

Abstract

Scanning magnetometry with nitrogen-vacancy (NV) centers in diamond has led to significant advances in the sensitive imaging of magnetic systems. The spatial resolution of the technique, however, remains limited to tens to hundreds of nanometers, even for probes where NV centers are engineered within 10 nm from the tip apex. Here, we present a correlated investigation of the crucial parameters that determine the spatial resolution: the mechanical and magnetic stand-off distances, as well as the subsurface NV center depth in diamond. We study their contributions using mechanical approach curves, photoluminescence measurements, magnetometry scans, and nuclear magnetic resonance (NMR) spectroscopy of surface adsorbates. We first show that the stand-off distance is mainly limited by features on the surface of the diamond tip, hindering mechanical access. Next, we demonstrate that frequency-modulated (FM) atomic force microscopy feedback partially overcomes this issue, leading to closer and more consistent magnetic stand-off distances (26–87 nm) compared with the more common amplitude-modulated feedback (43–128 nm). FM operation thus permits improved magnetic imaging of sub-100-nm spin textures, shown for the spin cycloid in BiFeO<sub>3</sub> and domain walls in a CoFeB synthetic antiferromagnet. Finally, by examining <sup>1</sup>H and <sup>19</sup>F NMR signals in soft contact with a polytetrafluoroethylene surface, we demonstrate a minimum NV-to-sample distance of 7.9 ± 0.4 nm.

Figshare
Openalex Percentile: Top 61%
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

MinimizingSensor-Sample Distances in Scanning Nitrogen-VacancyMagnetometry · Figshare (2025) | TGRS Research Map | TGRS