The lesser trochanter profile is an accurate and reliable measure of femoral rotation for intramedullary nailing

\nIntroduction: The lesser trochanter profile (LTP) method is an intraoperative fluoroscopic technique that can assess the femoral version and limit malrotation. The purpose of this study was to directly assess the accuracy and reliability of the LTP method, as well as determine the incidence of malrotation produced by this technique. Methods: Three groups of observers (fellowship-trained orthopedic surgeons, orthopedic residents, and medical students) utilized the LTP method to replicate pre-imaged rotation angles on a cadaveric femur bone. Recorded outcomes include rotational error and number of attempts. Accuracy and interobserver reliability were assessed by rotational error and the interclass correlation coefficient (ICC), respectively. Results: Accuracy was within 3° for all three groups. ICC between each group was greater than 0.99. There was no statistical difference between the accuracy of fellowship-trained surgeons, orthopedic residents, and medical students. Medical students on average required more attempts to obtain their final image compared to fellowship-trained surgeons. There was no statistical difference in the number of attempts between residents and fellowship-trained surgeons. Conclusion: None of the LTP measurements were greater than 15°, the clinical threshold for malrotation. The average error of the observers was less than 3°, demonstrating that the LTP is an effective method of assessing the femoral version. There was no statistically significant difference between the observers, indicating that this technique is reliable and easy to use. Ultimately, the LTP method is easily reproducible for surgeons to avoid femoral malrotation.\n

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-09-20
DOI
https://doi.org/10.1051/sicotj/2024036/pdf
Primary Topic
Genetic Mapping and Diversity in Plants and Animals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The lesser trochanter profile is an accurate and reliable measure of femoral rotation for intramedullary nailing

Springer Link (Chiba Institute of Technology)
Genetic Mapping and Diversity in Plants and Animals
article

The lesser trochanter profile is an accurate and reliable measure of femoral rotation for intramedullary nailing

article en

Abstract

\nIntroduction: The lesser trochanter profile (LTP) method is an intraoperative fluoroscopic technique that can assess the femoral version and limit malrotation. The purpose of this study was to directly assess the accuracy and reliability of the LTP method, as well as determine the incidence of malrotation produced by this technique. Methods: Three groups of observers (fellowship-trained orthopedic surgeons, orthopedic residents, and medical students) utilized the LTP method to replicate pre-imaged rotation angles on a cadaveric femur bone. Recorded outcomes include rotational error and number of attempts. Accuracy and interobserver reliability were assessed by rotational error and the interclass correlation coefficient (ICC), respectively. Results: Accuracy was within 3° for all three groups. ICC between each group was greater than 0.99. There was no statistical difference between the accuracy of fellowship-trained surgeons, orthopedic residents, and medical students. Medical students on average required more attempts to obtain their final image compared to fellowship-trained surgeons. There was no statistical difference in the number of attempts between residents and fellowship-trained surgeons. Conclusion: None of the LTP measurements were greater than 15°, the clinical threshold for malrotation. The average error of the observers was less than 3°, demonstrating that the LTP is an effective method of assessing the femoral version. There was no statistically significant difference between the observers, indicating that this technique is reliable and easy to use. Ultimately, the LTP method is easily reproducible for surgeons to avoid femoral malrotation.\n

Springer Link (Chiba Institute of Technology)
Gender equality
Openalex Percentile: Top 50%
Genetic Mapping and Diversity in Plants and Animals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.