Flexible Eyelid Pressureand Motion Dual-Mode SensorUsing Electric Breakdown-Induced Piezoresistivity and Electrical PotentialSensing

Multiple ocular surface disorders are associated with the mechanical properties of the interface between the eyelid and cornea. Determining eyelid pressure is vital for diagnosing and preventing these disorders. However, current measurements rely on flat piezoresistive pressure sensor arrays that lack eye-motion sensing capabilities, resulting in discomfort and measurement inaccuracies. This study develops and evaluates an integrated, curved, flexible, dual-mode sensor array for simultaneous eyelid pressure and motion detection, using soft thermoplastic polyurethane (TPU) films as transducers and substrates. A novel manufacturing method based on the electrical breakdown of the TPU film enables piezoresistive pressure sensing, achieving a pressure detection limit of 3.2 Pa. Eyelid motion is measured through electrical potential sensing, where changes in eyelid position alter the electric potentials at the receiving electrodes. The sensor’s performance was validated with animal experiments involving rabbit eyes; eyelid pressure was successfully measured during eye opening and blinking. This flexible dual-mode eyelid sensor holds promise for monitoring eyelid pressure and assessing ocular surface disorders.

Publication Details

Journal
Figshare
Published
2025-01-22
DOI
https://doi.org/10.1021/acsami.4c21230.s001
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible Eyelid Pressureand Motion Dual-Mode SensorUsing Electric Breakdown-Induced Piezoresistivity and Electrical PotentialSensing

Figshare
Advanced Sensor and Energy Harvesting Materials
article

Flexible Eyelid Pressureand Motion Dual-Mode SensorUsing Electric Breakdown-Induced Piezoresistivity and Electrical PotentialSensing

article en

Abstract

Multiple ocular surface disorders are associated with the mechanical properties of the interface between the eyelid and cornea. Determining eyelid pressure is vital for diagnosing and preventing these disorders. However, current measurements rely on flat piezoresistive pressure sensor arrays that lack eye-motion sensing capabilities, resulting in discomfort and measurement inaccuracies. This study develops and evaluates an integrated, curved, flexible, dual-mode sensor array for simultaneous eyelid pressure and motion detection, using soft thermoplastic polyurethane (TPU) films as transducers and substrates. A novel manufacturing method based on the electrical breakdown of the TPU film enables piezoresistive pressure sensing, achieving a pressure detection limit of 3.2 Pa. Eyelid motion is measured through electrical potential sensing, where changes in eyelid position alter the electric potentials at the receiving electrodes. The sensor’s performance was validated with animal experiments involving rabbit eyes; eyelid pressure was successfully measured during eye opening and blinking. This flexible dual-mode eyelid sensor holds promise for monitoring eyelid pressure and assessing ocular surface disorders.

Figshare
Openalex Percentile: Top 54%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.