Stable AirPlastron Prolongs Biofluid Repellency ofSubmerged Superhydrophobic Surfaces

Superhydrophobic surfaces find applications in numerous biomedical scenarios, requiring the repellence of biofluids and biomolecules. Plastron, the trapped air between a superhydrophobic surface and a wetting liquid, plays a pivotal role in biofluid repellency. A key challenge, however, is the often short-lived plastron stability in biofluids and the lack of knowledge surrounding it. Plastron stability refers to the duration for which a surface remains in the Cassie state before transitioning to the fully wetting Wenzel state. Here, a submersion test with real-time optical monitoring is used to determine the plastron lifetime of different superhydrophobic surfaces upon immersion in various biofluids. We find that biofluids of all types exhibit shorter plastron lifetimes compared to pure water, which is attributed to their lower surface tension and biomolecular adsorption through hydrophobic–hydrophobic interactions. Proteins and glucose are identified as the major contributors to plastron dissipation in fetal bovine serum-based biofluids. Plastron minimizes the solid–liquid interface, reducing biomolecular adsorption, making its stability crucial for biofluid repellence. Thus, the effects of surface texture, feature size, Cassie solid fraction, Wenzel dimensionless roughness, and surface chemistry on plastron stability are investigated. Our key findings indicate that prolonged plastron stability and thus enhanced biofluid repellency are achieved through a combination of larger plastron volumes, increased Wenzel roughness degrees, greater Cassie solid fractions, and smaller feature sizes. We demonstrate that with optimized parameters, our surface design can maintain plastron stability and sustain a consistent solid–liquid area fraction for over 120 h in complex biofluids containing high levels of protein and glucose, underscoring a robust design for long-term use in biomedical and antifouling applications. This research is essential for advancing the design of superhydrophobic surfaces that effectively resist biofouling in diverse medical and engineering settings.

Publication Details

Journal
Figshare
Published
2025-01-15
DOI
https://doi.org/10.1021/acs.langmuir.4c04259.s001
Primary Topic
Surface Modification and Superhydrophobicity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stable AirPlastron Prolongs Biofluid Repellency ofSubmerged Superhydrophobic Surfaces

Figshare
Surface Modification and Superhydrophobicity
article

Stable AirPlastron Prolongs Biofluid Repellency ofSubmerged Superhydrophobic Surfaces

article en

Abstract

Superhydrophobic surfaces find applications in numerous biomedical scenarios, requiring the repellence of biofluids and biomolecules. Plastron, the trapped air between a superhydrophobic surface and a wetting liquid, plays a pivotal role in biofluid repellency. A key challenge, however, is the often short-lived plastron stability in biofluids and the lack of knowledge surrounding it. Plastron stability refers to the duration for which a surface remains in the Cassie state before transitioning to the fully wetting Wenzel state. Here, a submersion test with real-time optical monitoring is used to determine the plastron lifetime of different superhydrophobic surfaces upon immersion in various biofluids. We find that biofluids of all types exhibit shorter plastron lifetimes compared to pure water, which is attributed to their lower surface tension and biomolecular adsorption through hydrophobic–hydrophobic interactions. Proteins and glucose are identified as the major contributors to plastron dissipation in fetal bovine serum-based biofluids. Plastron minimizes the solid–liquid interface, reducing biomolecular adsorption, making its stability crucial for biofluid repellence. Thus, the effects of surface texture, feature size, Cassie solid fraction, Wenzel dimensionless roughness, and surface chemistry on plastron stability are investigated. Our key findings indicate that prolonged plastron stability and thus enhanced biofluid repellency are achieved through a combination of larger plastron volumes, increased Wenzel roughness degrees, greater Cassie solid fractions, and smaller feature sizes. We demonstrate that with optimized parameters, our surface design can maintain plastron stability and sustain a consistent solid–liquid area fraction for over 120 h in complex biofluids containing high levels of protein and glucose, underscoring a robust design for long-term use in biomedical and antifouling applications. This research is essential for advancing the design of superhydrophobic surfaces that effectively resist biofouling in diverse medical and engineering settings.

Figshare
Openalex Percentile: Top 54%
Surface Modification and Superhydrophobicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.