Investigation of the positioning accuracy of the Cat’s Eye as a reference position in asphere-measuring interferometry

\nFast and accurate asphere and freeform measurements are in high demand by the optics manufacturing industry. Interferometric methods such as tilted-wave interferometry meet these demands but require accurate surface positioning of the specimen along the optical axis, since such measurements are sensitive to such positioning errors. In this work the Cat’s Eye position will be investigated in terms of accuracy and repeatability as a reference position for surface positioning in tilted-wave interferometry. For this purpose, a two-regime method for specimen alignment using different optimization criteria is investigated and its repeatability is evaluated. Accurate and reproducible positioning into the Cat’s Eye position together with interferometric movement tracking will allow accurate specimen positioning along the optical axis, which will significantly reduce the surface measurement errors associated with such misalignment and improve the overall measurement uncertainty.\n

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-10-31
DOI
https://doi.org/10.1051/epjconf/202430902012/pdf
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the positioning accuracy of the Cat’s Eye as a reference position in asphere-measuring interferometry

Springer Link (Chiba Institute of Technology)
Optical measurement and interference techniques
article

Investigation of the positioning accuracy of the Cat’s Eye as a reference position in asphere-measuring interferometry

article en

Abstract

\nFast and accurate asphere and freeform measurements are in high demand by the optics manufacturing industry. Interferometric methods such as tilted-wave interferometry meet these demands but require accurate surface positioning of the specimen along the optical axis, since such measurements are sensitive to such positioning errors. In this work the Cat’s Eye position will be investigated in terms of accuracy and repeatability as a reference position for surface positioning in tilted-wave interferometry. For this purpose, a two-regime method for specimen alignment using different optimization criteria is investigated and its repeatability is evaluated. Accurate and reproducible positioning into the Cat’s Eye position together with interferometric movement tracking will allow accurate specimen positioning along the optical axis, which will significantly reduce the surface measurement errors associated with such misalignment and improve the overall measurement uncertainty.\n

Springer Link (Chiba Institute of Technology)
Industry, innovation and infrastructure
Openalex Percentile: Top 60%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.