The efficacy of helium generated cold atmospheric plasma for skin disinfection

The present study was performed to evaluate the disinfecting effects of helium-generated cold atmospheric plasma (He-CAP) against bacteria. The study further explored the biosafety of He-CAP. Antibacterial effects of He-CAP were evaluated on gram-positive Staphylococcus aureus and gram-negative Pseudomonas aeruginosa. Optimization was done by testing the bactericidal effects of He-CAP against different combinations of working parameters including exposure time, gas flow rate and applied voltage. Cell membrane integrity was evaluated by amount of protein leakage and scanning electron microscopy (SEM). Biosafety evaluation of He-CAP was done on mice. Optimization of working parameters showed highest bactericidal effects at gas flow rate of 5 litres per minute (LPM), 5 min exposure and applied voltage at 2.5 kV (p–p) at 10 mm distance maintained between the plasma jet and bacterial cultures. Protein leakage and SEM images confirmed membrane rupture. Skin irritation and sensitivity was not observed in mice. In conclusion, He-CAP has promising bactericidal effects.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.29041080
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The efficacy of helium generated cold atmospheric plasma for skin disinfection

Figshare
Plasma Applications and Diagnostics
article

The efficacy of helium generated cold atmospheric plasma for skin disinfection

article en

Abstract

The present study was performed to evaluate the disinfecting effects of helium-generated cold atmospheric plasma (He-CAP) against bacteria. The study further explored the biosafety of He-CAP. Antibacterial effects of He-CAP were evaluated on gram-positive Staphylococcus aureus and gram-negative Pseudomonas aeruginosa. Optimization was done by testing the bactericidal effects of He-CAP against different combinations of working parameters including exposure time, gas flow rate and applied voltage. Cell membrane integrity was evaluated by amount of protein leakage and scanning electron microscopy (SEM). Biosafety evaluation of He-CAP was done on mice. Optimization of working parameters showed highest bactericidal effects at gas flow rate of 5 litres per minute (LPM), 5 min exposure and applied voltage at 2.5 kV (p–p) at 10 mm distance maintained between the plasma jet and bacterial cultures. Protein leakage and SEM images confirmed membrane rupture. Skin irritation and sensitivity was not observed in mice. In conclusion, He-CAP has promising bactericidal effects.

Figshare
Openalex Percentile: Top 39%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.