An Automatic Injection Device and the Method for Carbon and Oxygen Isotopes Analyses of Carbon Monoxide

Carbon monoxide (CO) is an essential component of air, and it arises from anthropogenic sources and natural sources. These different sources of CO have significant differences in carbon and oxygen isotopic values, therefore the carbon and oxygen isotopic composition of CO is important for the sources and sink of CO in environmental research. In addition, the isotopic composition of CO in coal beds can help to explore the origin and deposit of coal, the self-heating and spontaneous combustion of coal, which benefits for coal mine safety management. At present, CO isotopic compositions are mainly analyzed by optical spectroscopy or gas chromatography-isotope ratio mass spectrometer (GC-IRMS). The optical spectroscopy method is mainly used in the studies on theoretical CO isotope effects, but its analytical precision is low. GC-IRMS for CO isotopic composition analysis usually requires manual injection, resulting in low efficiency, and it is easily influenced by operation. Meanwhile, both N2 and CO2 will produce interfering ions and affect the accuracy of CO isotope analysis. In this study, a device of automatic CO gas separation, purification, and injection was developed and combined with IRMS for determination of isotope composition of CO. The impurities, CO2 and water molecules in the mixed sample gas were discharged by Nafion tube and a liquid nitrogen cold trap. After nitrogen and CO were separated by Molesive5A chromatographic column, nitrogen was eliminated by valve switching technique, and therefore only the purified CO entered the IRMS for analyzing. By calling the reserved interface of IRMS, the automatic lifting of the cold trap and switching of the 8-pass valve and 4-pass valve was realized. The CO gas concentration and the total peak area of ions at m/z 28, 29 and 30 show a good linear relationship with the correlation coefficient (R2) of 0.999 when the CO gas concentration ranges from 300 to 20 000 μL/L. The standard deviations of δ13C and δ18O are within 0.4‰ when the CO concentration is between 1 000 and 20 000 μL/L. In the repeating analysis of a long term (about 6 months), the results of δ13C and δ18O of 4 000 μL/L CO standards are stable and the standard deviations are 0.26‰ and 0.47‰ (n=20), respectively. The standard deviations of δ13C and δ18O of the CO in natural samples from Coal Bed Methane are less than 0.5‰. Based on the above test results, the conclusions can be obtained that the accuracy and stability of the automatic injection equipment coupled to IRMS meet the requirements for the determination of carbon and oxygen isotopes in CO. However, when CO gas concentration is lower than 1000 μL/L, the carbon and oxygen isotope analysis are greatly biased by IRMS. Further protocol is needed to improve the accuracy and precision of isotopic analysis for low-concentration samples.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.7538/zpxb.2024.0150
Primary Topic
Coal Properties and Utilization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Automatic Injection Device and the Method for Carbon and Oxygen Isotopes Analyses of Carbon Monoxide

SHILAP Revista de lepidopterología
Coal Properties and Utilization
article

An Automatic Injection Device and the Method for Carbon and Oxygen Isotopes Analyses of Carbon Monoxide

article en

Abstract

Carbon monoxide (CO) is an essential component of air, and it arises from anthropogenic sources and natural sources. These different sources of CO have significant differences in carbon and oxygen isotopic values, therefore the carbon and oxygen isotopic composition of CO is important for the sources and sink of CO in environmental research. In addition, the isotopic composition of CO in coal beds can help to explore the origin and deposit of coal, the self-heating and spontaneous combustion of coal, which benefits for coal mine safety management. At present, CO isotopic compositions are mainly analyzed by optical spectroscopy or gas chromatography-isotope ratio mass spectrometer (GC-IRMS). The optical spectroscopy method is mainly used in the studies on theoretical CO isotope effects, but its analytical precision is low. GC-IRMS for CO isotopic composition analysis usually requires manual injection, resulting in low efficiency, and it is easily influenced by operation. Meanwhile, both N2 and CO2 will produce interfering ions and affect the accuracy of CO isotope analysis. In this study, a device of automatic CO gas separation, purification, and injection was developed and combined with IRMS for determination of isotope composition of CO. The impurities, CO2 and water molecules in the mixed sample gas were discharged by Nafion tube and a liquid nitrogen cold trap. After nitrogen and CO were separated by Molesive5A chromatographic column, nitrogen was eliminated by valve switching technique, and therefore only the purified CO entered the IRMS for analyzing. By calling the reserved interface of IRMS, the automatic lifting of the cold trap and switching of the 8-pass valve and 4-pass valve was realized. The CO gas concentration and the total peak area of ions at m/z 28, 29 and 30 show a good linear relationship with the correlation coefficient (R2) of 0.999 when the CO gas concentration ranges from 300 to 20 000 μL/L. The standard deviations of δ13C and δ18O are within 0.4‰ when the CO concentration is between 1 000 and 20 000 μL/L. In the repeating analysis of a long term (about 6 months), the results of δ13C and δ18O of 4 000 μL/L CO standards are stable and the standard deviations are 0.26‰ and 0.47‰ (n=20), respectively. The standard deviations of δ13C and δ18O of the CO in natural samples from Coal Bed Methane are less than 0.5‰. Based on the above test results, the conclusions can be obtained that the accuracy and stability of the automatic injection equipment coupled to IRMS meet the requirements for the determination of carbon and oxygen isotopes in CO. However, when CO gas concentration is lower than 1000 μL/L, the carbon and oxygen isotope analysis are greatly biased by IRMS. Further protocol is needed to improve the accuracy and precision of isotopic analysis for low-concentration samples.

SHILAP Revista de lepidopterología
Fujian Institute of Oceanography (CN)
Openalex Percentile: Top 46%
Coal Properties and Utilization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.