Virucidal efficacy of pulsed light UV irradiation_RAW data.pptx

In emergency medical situations, individuals are often exposed to unknown pathogenic viruses and bacteria. Therefore, the use of portable pulsed light UV disinfection devices in emergency and critical care centers has increased. However, the virucidal efficacy of these devices remain unclear. The present study aimed to examine the virucidal efficacy of a portable pulsed light UV disinfection device against various viruses. The efficacy of a portable pulsed light UV disinfection device, obtained from ClearPulse® (COMET CORPORATION, Tokyo, Japan), was investigated against feline calicivirus, influenza A virus, herpes simplex virus type 2, poliovirus type 3, and severe acute respiratory syndrome coronavirus 2. The device was tested at various irradiation times (1, 5, and 10 s) and irradiation distances (1, 5, and 10 cm). The portable pulsed light UV disinfection device was effective against the tested viruses at an irradiation distance ≤ 5 cm and an irradiation time ≥ 5 s. These results indicate that the portable pulsed light UV disinfection device is effective for the rapid disinfection of surfaces against viruses, making it highly useful in emergency and critical care situations.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.28523624
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Virucidal efficacy of pulsed light UV irradiation_RAW data.pptx

Figshare
Infection Control and Ventilation
article

Virucidal efficacy of pulsed light UV irradiation_RAW data.pptx

article en

Abstract

In emergency medical situations, individuals are often exposed to unknown pathogenic viruses and bacteria. Therefore, the use of portable pulsed light UV disinfection devices in emergency and critical care centers has increased. However, the virucidal efficacy of these devices remain unclear. The present study aimed to examine the virucidal efficacy of a portable pulsed light UV disinfection device against various viruses. The efficacy of a portable pulsed light UV disinfection device, obtained from ClearPulse® (COMET CORPORATION, Tokyo, Japan), was investigated against feline calicivirus, influenza A virus, herpes simplex virus type 2, poliovirus type 3, and severe acute respiratory syndrome coronavirus 2. The device was tested at various irradiation times (1, 5, and 10 s) and irradiation distances (1, 5, and 10 cm). The portable pulsed light UV disinfection device was effective against the tested viruses at an irradiation distance ≤ 5 cm and an irradiation time ≥ 5 s. These results indicate that the portable pulsed light UV disinfection device is effective for the rapid disinfection of surfaces against viruses, making it highly useful in emergency and critical care situations.

Figshare
Good health and well-being
Openalex Percentile: Top 36%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.