Polyurethane Surface\nwith Antibacterial and Antifouling\nProperties Enabled via Surface Grafting of Imidazolium Salt Chitosan\nGraft-Polyzwitterionic Copolymer

Protein adsorption and bacterial colonization on implantable\nmedical\ndevices often cause postoperative infections coupled with complications,\neven leading to function failure of implantable devices. To reduce\nthese risks, it is essential and feasible for these devices to improve\ntheir antibacterial and antifouling capabilities by surface modification.\nIn this work, an antibacterial and hydrophilic polymer, IMCTS–PMPC-PAA,\nwas developed by a one-step in situ graft polymerization of imidazolium\nsalt chitosan (IMCTS), 2-methacryloyloxyethyl phosphorylcholine (MPC),\nand acrylic acid (AA). Then, it was grafted onto the polydopamine/polyethylenimine\n(PDA/PEI)-modified polyurethane (PU) surface to form a PDA/PEI-IMCTS-PMPC\ncoating. The antibacterial and antifouling performance of the PDA/PEI-IMCTS-PMPC\ncoating was tested by the plate counting method and the antiprotein\nadsorption assay. The results showed that the coating had excellent\nantibacterial activity compared with bare PU, with antibacterial rates\nof 99.94 ± 0.06 and 99.82 ± 0.09% against Escherichia coli and Staphylococcus\naureus, respectively. Meanwhile, the antiprotein adsorption\nperformance of the coating was also excellent, with antiprotein adsorption\nrates of 85.78 ± 2.14 and 89.30 ± 2.12% for lysozyme (LYS)\nand bovine serum albumin (BSA), respectively. In addition, the coating\nstability test, platelet adhesion and hemolysis tests, and cytotoxicity\nassay demonstrated the good stability and biocompatibility of the\nPDA/PEI-IMCTS-PMPC coating. Overall, this study offers a viable approach\nto the development of coatings for implantable medical devices.

Publication Details

Journal
Figshare
Published
2024-09-30
DOI
https://doi.org/10.1021/acsapm.4c01908.s002
Primary Topic
Polymer Surface Interaction Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polyurethane Surface\nwith Antibacterial and Antifouling\nProperties Enabled via Surface Grafting of Imidazolium Salt Chitosan\nGraft-Polyzwitterionic Copolymer

Figshare
Polymer Surface Interaction Studies
article

Polyurethane Surface\nwith Antibacterial and Antifouling\nProperties Enabled via Surface Grafting of Imidazolium Salt Chitosan\nGraft-Polyzwitterionic Copolymer

article en

Abstract

Protein adsorption and bacterial colonization on implantable\nmedical\ndevices often cause postoperative infections coupled with complications,\neven leading to function failure of implantable devices. To reduce\nthese risks, it is essential and feasible for these devices to improve\ntheir antibacterial and antifouling capabilities by surface modification.\nIn this work, an antibacterial and hydrophilic polymer, IMCTS–PMPC-PAA,\nwas developed by a one-step in situ graft polymerization of imidazolium\nsalt chitosan (IMCTS), 2-methacryloyloxyethyl phosphorylcholine (MPC),\nand acrylic acid (AA). Then, it was grafted onto the polydopamine/polyethylenimine\n(PDA/PEI)-modified polyurethane (PU) surface to form a PDA/PEI-IMCTS-PMPC\ncoating. The antibacterial and antifouling performance of the PDA/PEI-IMCTS-PMPC\ncoating was tested by the plate counting method and the antiprotein\nadsorption assay. The results showed that the coating had excellent\nantibacterial activity compared with bare PU, with antibacterial rates\nof 99.94 ± 0.06 and 99.82 ± 0.09% against Escherichia coli and Staphylococcus\naureus, respectively. Meanwhile, the antiprotein adsorption\nperformance of the coating was also excellent, with antiprotein adsorption\nrates of 85.78 ± 2.14 and 89.30 ± 2.12% for lysozyme (LYS)\nand bovine serum albumin (BSA), respectively. In addition, the coating\nstability test, platelet adhesion and hemolysis tests, and cytotoxicity\nassay demonstrated the good stability and biocompatibility of the\nPDA/PEI-IMCTS-PMPC coating. Overall, this study offers a viable approach\nto the development of coatings for implantable medical devices.

Figshare
Openalex Percentile: Top 65%
Polymer Surface Interaction Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.