MCNP Simulation of NaI Detector for PGNAA Technology

Sodium iodide (NaI) detector has wide applications in Prompt Gamma-ray Neutron Activation Analysis (PGNAA) due to its excellent detection efficiency and relatively low cost. In order to obtain the response of the detector to gamma-rays during PGNAA measurement process,a Monte Carlo model was established for the NaI detector to simulate the transport processes of neutrons and gamma-rays. Measurements and analyses were conducted on standard point sources of 60Co,137Cs,152Eu,133Ba,and 241Am,as well as a waterborne source of 137Cs. These measurements were compared with MCNP simulation calculations,and the results demonstrated agreement between the two methodologies. Then,measurements were conducted on aqueous solutions using a D-D neutron generator,and the 2.223 MeV characteristic gamma-ray produced by the H element radiative capture reaction was analyzed. The research results show that the deviations between MCNP simulation calculations of characteristic peaks for the H element and experimental measurements were consistently within 13%,demonstrating that the NaI measurement system model established by MCNP can simulate the transport processes of gamma and neutrons,laying a foundation for the subsequent optimization of the system and other related work.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.7538/tws.2024.youxian.068
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MCNP Simulation of NaI Detector for PGNAA Technology

SHILAP Revista de lepidopterología
Nuclear Physics and Applications
article

MCNP Simulation of NaI Detector for PGNAA Technology

article en

Abstract

Sodium iodide (NaI) detector has wide applications in Prompt Gamma-ray Neutron Activation Analysis (PGNAA) due to its excellent detection efficiency and relatively low cost. In order to obtain the response of the detector to gamma-rays during PGNAA measurement process,a Monte Carlo model was established for the NaI detector to simulate the transport processes of neutrons and gamma-rays. Measurements and analyses were conducted on standard point sources of 60Co,137Cs,152Eu,133Ba,and 241Am,as well as a waterborne source of 137Cs. These measurements were compared with MCNP simulation calculations,and the results demonstrated agreement between the two methodologies. Then,measurements were conducted on aqueous solutions using a D-D neutron generator,and the 2.223 MeV characteristic gamma-ray produced by the H element radiative capture reaction was analyzed. The research results show that the deviations between MCNP simulation calculations of characteristic peaks for the H element and experimental measurements were consistently within 13%,demonstrating that the NaI measurement system model established by MCNP can simulate the transport processes of gamma and neutrons,laying a foundation for the subsequent optimization of the system and other related work.

SHILAP Revista de lepidopterología
Inner Mongolia Autonomous Region Meteorological Bureau (CN), East China University of Technology (CN), Nanjing University of Aeronautics and Astronautics (CN)
Openalex Percentile: Top 55%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.