Additional file 2 of Encrustations on ureteral stents from patients without urinary tract infection reveal distinct urotypes and a low bacterial load

Figure S1. Additional SEM images representing the presence of fungi, coverage by EPS and bacterial load. Figure S2. a Standard curve of serially diluted recDNA containing the E. coli 16S rRNA gene (data from 14 independent experiments). The 16S rRNA gene copy number was plotted against the calculated gene copy number (slope = 1.03011 ± 0.07591, intercept − 0.16974 ± 0.59028, R2 = 0.98397, n = 14). Inter-run calibration was performed using the recDNA. b Bacteria equivalents assessed by NGS plotted vs. 16S rRNA gene copies as assessed by qPCR. 16S qPCR correlated with normalized NGS reads (Spearman ranks r = 0.620, p < 0.0001, 95% CI 0.4642 to 0.7390). Table S3. OTUs present in more than 50% of the samples. Figure S4. Rarefaction curves of the 86 sequenced samples. Figure S5. XRD signals and comparison with expected patterns from the COD database. (DOCX 2772 kb)

Institutions

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.7992083
Primary Topic
Kidney Stones and Urolithiasis Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Additional file 2 of Encrustations on ureteral stents from patients without urinary tract infection reveal distinct urotypes and a low bacterial load

Figshare
Kidney Stones and Urolithiasis Treatments
article

Additional file 2 of Encrustations on ureteral stents from patients without urinary tract infection reveal distinct urotypes and a low bacterial load

article en

Abstract

Figure S1. Additional SEM images representing the presence of fungi, coverage by EPS and bacterial load. Figure S2. a Standard curve of serially diluted recDNA containing the E. coli 16S rRNA gene (data from 14 independent experiments). The 16S rRNA gene copy number was plotted against the calculated gene copy number (slope = 1.03011 ± 0.07591, intercept − 0.16974 ± 0.59028, R2 = 0.98397, n = 14). Inter-run calibration was performed using the recDNA. b Bacteria equivalents assessed by NGS plotted vs. 16S rRNA gene copies as assessed by qPCR. 16S qPCR correlated with normalized NGS reads (Spearman ranks r = 0.620, p < 0.0001, 95% CI 0.4642 to 0.7390). Table S3. OTUs present in more than 50% of the samples. Figure S4. Rarefaction curves of the 86 sequenced samples. Figure S5. XRD signals and comparison with expected patterns from the COD database. (DOCX 2772 kb)

Figshare
Helmholtz Centre for Environmental Research (DE), Kantonsspital St. Gallen (CH), Microsynth (Switzerland) (CH), Zentrum für Labormedizin (CH), Swiss Federal Laboratories for Materials Science and Technology (CH)
Openalex Percentile: Top 36%
Kidney Stones and Urolithiasis Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Additional file 2 of Encrustations on ureteral stents from patients without urinary tract infection reveal distinct urotypes and a low bacterial load · Figshare (2025) | TGRS Research Map | TGRS