Study on Improving Condensing Capacity of 30B Container

Aiming at the insufficient condensation capacity of the 30B vessel in the late stage of receiving in the current uranium enrichment plant,a copper triangular heat dissipation rib was designed,and the heat dissipation performance of the 30B vessel in the cold air box was simulated based on Flow simulation,and the heat dissipation rib was optimized. The results show that the best heat dissipation effect is achieved when the forced air cooling wind direction and the impact angle of the cylindrical container are 180°,and the container condensation efficiency is increased by 14.5% on average at 263.15 K,wind speed of 3 m/s,calculation length of 2400 s,and 70 cooling ribs compared with that when there is no loading of cooling ribs,and the average cooling efficiency is improved by 14.9% after optimizing the design of cooling ribs,and the cooling efficiency is increased by 19.9%,and at 248.15 K,with a wind speed of 3 m/s,the average thermal efficiency is improved by 30.4%. It proves that the 30B container can improve the thermal efficiency of the container after loading the external copper heat sink,which lays the foundation for the subsequent popularization of 30B direct charging.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.7538/tws.2024.youxian.094
Primary Topic
Nuclear Engineering Thermal-Hydraulics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Improving Condensing Capacity of 30B Container

SHILAP Revista de lepidopterología
Nuclear Engineering Thermal-Hydraulics
article

Study on Improving Condensing Capacity of 30B Container

article en

Abstract

Aiming at the insufficient condensation capacity of the 30B vessel in the late stage of receiving in the current uranium enrichment plant,a copper triangular heat dissipation rib was designed,and the heat dissipation performance of the 30B vessel in the cold air box was simulated based on Flow simulation,and the heat dissipation rib was optimized. The results show that the best heat dissipation effect is achieved when the forced air cooling wind direction and the impact angle of the cylindrical container are 180°,and the container condensation efficiency is increased by 14.5% on average at 263.15 K,wind speed of 3 m/s,calculation length of 2400 s,and 70 cooling ribs compared with that when there is no loading of cooling ribs,and the average cooling efficiency is improved by 14.9% after optimizing the design of cooling ribs,and the cooling efficiency is increased by 19.9%,and at 248.15 K,with a wind speed of 3 m/s,the average thermal efficiency is improved by 30.4%. It proves that the 30B container can improve the thermal efficiency of the container after loading the external copper heat sink,which lays the foundation for the subsequent popularization of 30B direct charging.

SHILAP Revista de lepidopterología
Beijing Research Institute of Uranium Geology (CN)
Affordable and clean energy
Openalex Percentile: Top 40%
Nuclear Engineering Thermal-Hydraulics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on Improving Condensing Capacity of 30B Container · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS