Modified Indigo Method to Quantify Ozone Diffusion from Nanobubbles

The use of nanobubbles to deliver ozone (O<sub>3</sub>) gas to natural and engineered water systems is an emerging technology. The long lifetime of nanobubbles prolongs the timeframe of O<sub>3</sub> mass transfer to aqueous solution, raising conflict with conventional methods used to quantify O<sub>3</sub>. Standard Method 4500-O3B is a colorimetric method that uses indigotrisulfonate (indigo) to measure residual aqueous O<sub>3</sub> concentration at a discrete timepoint. This discrete method does not account for gaseous O<sub>3</sub> that remains in nanobubbles at the time of the indigo absorbance measurement. In this study, a modified indigo method was developed to quantify the prolonged diffusion of O<sub>3</sub> from nanobubbles. The cumulative O<sub>3</sub> gas released by nanobubbles and dissolved into water was captured by measuring changes in indigo absorbance over time. The transfer of O<sub>3</sub> from nanobubbles into the aqueous phase occurred primarily within the first 4 days after treatment in natural waters. The effects of indigo concentration, water quality parameters, and H<sub>2</sub>O<sub>2</sub> were minimal over a week-long sample hold time. Sample storage at 4°C, consistent with the standard indigo method, is recommended in this study to prevent overcalculation of O<sub>3</sub> production. This is the first method developed for quantifying O<sub>3</sub> diffusion from nanobubbles.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.28929731
Primary Topic
Minerals Flotation and Separation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modified Indigo Method to Quantify Ozone Diffusion from Nanobubbles

Figshare
Minerals Flotation and Separation Techniques
article

Modified Indigo Method to Quantify Ozone Diffusion from Nanobubbles

article en

Abstract

The use of nanobubbles to deliver ozone (O<sub>3</sub>) gas to natural and engineered water systems is an emerging technology. The long lifetime of nanobubbles prolongs the timeframe of O<sub>3</sub> mass transfer to aqueous solution, raising conflict with conventional methods used to quantify O<sub>3</sub>. Standard Method 4500-O3B is a colorimetric method that uses indigotrisulfonate (indigo) to measure residual aqueous O<sub>3</sub> concentration at a discrete timepoint. This discrete method does not account for gaseous O<sub>3</sub> that remains in nanobubbles at the time of the indigo absorbance measurement. In this study, a modified indigo method was developed to quantify the prolonged diffusion of O<sub>3</sub> from nanobubbles. The cumulative O<sub>3</sub> gas released by nanobubbles and dissolved into water was captured by measuring changes in indigo absorbance over time. The transfer of O<sub>3</sub> from nanobubbles into the aqueous phase occurred primarily within the first 4 days after treatment in natural waters. The effects of indigo concentration, water quality parameters, and H<sub>2</sub>O<sub>2</sub> were minimal over a week-long sample hold time. Sample storage at 4°C, consistent with the standard indigo method, is recommended in this study to prevent overcalculation of O<sub>3</sub> production. This is the first method developed for quantifying O<sub>3</sub> diffusion from nanobubbles.

Figshare
Clean water and sanitation
Openalex Percentile: Top 58%
Minerals Flotation and Separation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.