Optimizing the processing conditions of ballasted flocculation of actual turbid river water

Ballasted flocculation is effective for fast turbidity removal in water treatment processes. However, there is a lack of specific information for setting the conditions for ballasted flocculation. To enhance the settling velocity and removal efficiency of ballasted flocculation of actual river water, the process parameters were examined at three turbidity levels. The optimum pH and dosages for ballasted flocculation were investigated based on the relationship between the water turbidity and the floc settling velocity at the three turbidity levels. A nonionic polymer flocculant was the most suitable for floc formation and achieved the lowest turbidity and highest settling velocity. Under the optimum processing conditions at the three turbidity levels, the treated water turbidity was ˂2 turbidity units (TU) and the floc settling velocity was ˃0.7 cm/s, which was 30 times that of conventional coagulation–sedimentation, reducing the floc settling time by 97% of those used in existing water treatment plants.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.28172229.v1
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing the processing conditions of ballasted flocculation of actual turbid river water

Figshare
Acute Ischemic Stroke Management
article

Optimizing the processing conditions of ballasted flocculation of actual turbid river water

article en

Abstract

Ballasted flocculation is effective for fast turbidity removal in water treatment processes. However, there is a lack of specific information for setting the conditions for ballasted flocculation. To enhance the settling velocity and removal efficiency of ballasted flocculation of actual river water, the process parameters were examined at three turbidity levels. The optimum pH and dosages for ballasted flocculation were investigated based on the relationship between the water turbidity and the floc settling velocity at the three turbidity levels. A nonionic polymer flocculant was the most suitable for floc formation and achieved the lowest turbidity and highest settling velocity. Under the optimum processing conditions at the three turbidity levels, the treated water turbidity was ˂2 turbidity units (TU) and the floc settling velocity was ˃0.7 cm/s, which was 30 times that of conventional coagulation–sedimentation, reducing the floc settling time by 97% of those used in existing water treatment plants.

Figshare
Clean water and sanitation
Openalex Percentile: Top 41%
Acute Ischemic Stroke Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.