Rock magnetic and micromagnetic modeling data for New Flow samples from Juan de Fuca Ridge

This zip file contains data presented in the submission “Internal stress enhances the stability of oceanic crust’s remanent magnetization” by Han et al., 2024.1. Folder “MicroMag” contains two subfolders and a MATLAB script.(1) Subfolder "MicroMag_Models" contains the MERRILL scripts and Patran geometries to reproduce the results.(2) Subfolder "MicroMag_Results" contains csv files to reproduce the results in Fig 4. Each File name contains composition, grain size and stress magnitude.The header format of each csv file is:# - The model index numberSx - The x-component of the unit vector describing the stress axisSy - The y-component of the unit vector describing the stress axisSz - The z-component of the unit vector describing the stress axis(Am^2) - The x-component of the net magnetic moment(Am^2) - The y-component of the net magnetic moment(Am^2) - The z-component of the net magnetic momentMs (A/m) - The saturation magnetizationVolume (m^3) - The volume of the modelled particle(3) Shrinkage_Model.m is a MATLAB script to reproduce the results in SI appendix Fig. S10.2. Folder “Figure05_DATA” has one Excel spreadsheet that contains all data plotted in Figure 5a–d.3. Folder “Rockmagnetism” contains five subfolders.(1) Subfolder “FORC_DATA” contains the FORC data of NF7 samples. We conducted FORC measurements with a field increment of 1.0 mT and a saturation field of 2.0 T using a Lake Shore vibrating sample magnetometer (VSM 8604) at China University of Geosciences (Wuhan).(2) Subfolder “IRM+DCD_DATA” contains an Excel spreadsheet that shows the isothermal remanent magnetization (IRM) acquisition data and backfield direct-current demagnetization (DCD) data with a saturation field of 2.0 T. These data were obtained using a Lake Shore vibrating sample magnetometer (VSM 8604) at China University of Geosciences (Wuhan).(3) Subfolder “high-saturation hys_DATA” contains the high-saturation-field (14.0 T) hysteresis loop data [applied field (mT), Magnetization (Am2)]. These experiments were conducted using a Quantum Design physical property measurement system (PPMS) at Wuhan National High Magnetic Field Center. Samples were cut into 2.5 mm*2.5 mm*3.0 mm in size using diamond wire with 0.35 mm diameter for the high-saturation-field measurements. The sweep rate was set to 3 mT/sec for applied fields in the [-2 T, 2 T] range, and 5 mT/sec for applied fields in the [-14 T, -2 T] and [2 T, 14 T] range.(4) Subfolder “low-saturation hys_DATA” contains the low-saturation-field (1.0 T and 2.0 T) hysteresis loop data [applied field (mT), Magnetization (Am2)] obtained using a Lake Shore vibrating sample magnetometer (VSM 8604) at China University of Geosciences (Wuhan).(5) Subfolder “low-temperature TFT_DATA” contains the low-temperature backfield direct-current demagnetization (DCD) data of NF7a1a and NF7b2a for thermal fluctuation tomography (TFT) modeling. We conducted these measurements using a Princeton Measurements Corporation vibrating sample magnetometer equipped with a low-temperature cryostat (LT-VSM) at the Institute for Rock Magnetism at the University of Minnesota. We measured backfield demagnetization curves at logarithmic increments from 2 mT to 1200 mT from 10 K to 300 K at 10 K.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.24087858
Primary Topic
Geomagnetism and Paleomagnetism Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rock magnetic and micromagnetic modeling data for New Flow samples from Juan de Fuca Ridge

Figshare
Geomagnetism and Paleomagnetism Studies
article

Rock magnetic and micromagnetic modeling data for New Flow samples from Juan de Fuca Ridge

article en

Abstract

This zip file contains data presented in the submission “Internal stress enhances the stability of oceanic crust’s remanent magnetization” by Han et al., 2024.1. Folder “MicroMag” contains two subfolders and a MATLAB script.(1) Subfolder "MicroMag_Models" contains the MERRILL scripts and Patran geometries to reproduce the results.(2) Subfolder "MicroMag_Results" contains csv files to reproduce the results in Fig 4. Each File name contains composition, grain size and stress magnitude.The header format of each csv file is:# - The model index numberSx - The x-component of the unit vector describing the stress axisSy - The y-component of the unit vector describing the stress axisSz - The z-component of the unit vector describing the stress axis(Am^2) - The x-component of the net magnetic moment(Am^2) - The y-component of the net magnetic moment(Am^2) - The z-component of the net magnetic momentMs (A/m) - The saturation magnetizationVolume (m^3) - The volume of the modelled particle(3) Shrinkage_Model.m is a MATLAB script to reproduce the results in SI appendix Fig. S10.2. Folder “Figure05_DATA” has one Excel spreadsheet that contains all data plotted in Figure 5a–d.3. Folder “Rockmagnetism” contains five subfolders.(1) Subfolder “FORC_DATA” contains the FORC data of NF7 samples. We conducted FORC measurements with a field increment of 1.0 mT and a saturation field of 2.0 T using a Lake Shore vibrating sample magnetometer (VSM 8604) at China University of Geosciences (Wuhan).(2) Subfolder “IRM+DCD_DATA” contains an Excel spreadsheet that shows the isothermal remanent magnetization (IRM) acquisition data and backfield direct-current demagnetization (DCD) data with a saturation field of 2.0 T. These data were obtained using a Lake Shore vibrating sample magnetometer (VSM 8604) at China University of Geosciences (Wuhan).(3) Subfolder “high-saturation hys_DATA” contains the high-saturation-field (14.0 T) hysteresis loop data [applied field (mT), Magnetization (Am2)]. These experiments were conducted using a Quantum Design physical property measurement system (PPMS) at Wuhan National High Magnetic Field Center. Samples were cut into 2.5 mm*2.5 mm*3.0 mm in size using diamond wire with 0.35 mm diameter for the high-saturation-field measurements. The sweep rate was set to 3 mT/sec for applied fields in the [-2 T, 2 T] range, and 5 mT/sec for applied fields in the [-14 T, -2 T] and [2 T, 14 T] range.(4) Subfolder “low-saturation hys_DATA” contains the low-saturation-field (1.0 T and 2.0 T) hysteresis loop data [applied field (mT), Magnetization (Am2)] obtained using a Lake Shore vibrating sample magnetometer (VSM 8604) at China University of Geosciences (Wuhan).(5) Subfolder “low-temperature TFT_DATA” contains the low-temperature backfield direct-current demagnetization (DCD) data of NF7a1a and NF7b2a for thermal fluctuation tomography (TFT) modeling. We conducted these measurements using a Princeton Measurements Corporation vibrating sample magnetometer equipped with a low-temperature cryostat (LT-VSM) at the Institute for Rock Magnetism at the University of Minnesota. We measured backfield demagnetization curves at logarithmic increments from 2 mT to 1200 mT from 10 K to 300 K at 10 K.

Figshare
Life below water
Openalex Percentile: Top 53%
Geomagnetism and Paleomagnetism Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.