Fractional exhaled nitric oxide and respiratory symptoms in central sterile supply department workers exposed to different ventilation systems

Objective: To verify the association between different types of ambient ventilation in Central Sterile Supply Department (CSSD), fractional exhaled nitric oxide (FeNO) values, and respiratory symptoms of workers . Methods: CSSD workers from five hospitals were evaluated in three different ventilation systems: negative air pressure, air conditioning, and natural ventilation. The prevalence of respiratory symptoms was evaluated by The European Community Respiratory Health Survey. The respiratory inflammatory response was evaluated utilizing FeNO level measurements. Results: There was a general prevalence of respiratory symptoms in 5% of the workers investigated; there was no association between respiratory symptoms and ventilation systems (<i>p</i> = 0.170). Of the total workers investigated, 22% had FeNO levels ≥ 25 parts per billion (ppb), considered above the normal range, and there was a statistically significant difference between ventilation systems (<i>p</i> = 0.009) favoring natural ventilation. Conclusion: Exposure to the natural ventilation system reduced the chance of developing FeNO levels ≥ 25 by 94.3%.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.28211707.v1
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fractional exhaled nitric oxide and respiratory symptoms in central sterile supply department workers exposed to different ventilation systems

Figshare
Infection Control and Ventilation
article

Fractional exhaled nitric oxide and respiratory symptoms in central sterile supply department workers exposed to different ventilation systems

article en

Abstract

Objective: To verify the association between different types of ambient ventilation in Central Sterile Supply Department (CSSD), fractional exhaled nitric oxide (FeNO) values, and respiratory symptoms of workers . Methods: CSSD workers from five hospitals were evaluated in three different ventilation systems: negative air pressure, air conditioning, and natural ventilation. The prevalence of respiratory symptoms was evaluated by The European Community Respiratory Health Survey. The respiratory inflammatory response was evaluated utilizing FeNO level measurements. Results: There was a general prevalence of respiratory symptoms in 5% of the workers investigated; there was no association between respiratory symptoms and ventilation systems (<i>p</i> = 0.170). Of the total workers investigated, 22% had FeNO levels ≥ 25 parts per billion (ppb), considered above the normal range, and there was a statistically significant difference between ventilation systems (<i>p</i> = 0.009) favoring natural ventilation. Conclusion: Exposure to the natural ventilation system reduced the chance of developing FeNO levels ≥ 25 by 94.3%.

Figshare
Openalex Percentile: Top 36%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.