Mathematical modeling of the effect of stent construction during endoluminal IRE for recanalization of an occluded metal stent

Intraluminal irreversible electroporation (IRE) can be used for recanalizing occluded metal stents. However, optimal IRE parameters for consistent effects across different stent designs remain unclear. The aim of this study was to simulate the process of stent recanalization <i>in silico</i> by employing finite element analysis. A virtual model of an occluded biliary stent with an experimental 3-electrode IRE catheter was developed. Electric field distribution, temperature changes, and potential ablation volumes were simulated across various parameters: IRE voltage (300 − 1300 V), stent wire width (0.1 − 0.5 mm) and stent mesh size (0.7 − 5.58 mm). Simulations incorporated five representative stent types commonly used in clinical practice. 685 unique simulations were conducted, analyzing 1162 unique values. Higher voltages generally led to larger ablation zones and increased temperatures. Thinner stent wires and larger mesh sizes also increased the extent of ablation zone. While in-stent ablation was largely independent of stent design, out-of-stent ablation was significantly impacted by mesh size and tissue thickness between the stent and irreversible electroporation electrodes. Voltages above 1000 V produced significant thermal effects, with substantial volumes of tissue heated above 50 °C. Specific stent designs exhibited variations in maximum temperature (72.1 − 83.1 °C) and ablation volume (8.7 − 14.7 mm<sup>3</sup>). Tailored IRE protocols for different stent designs are required due to differences in in- and out-stent ablation volumes. High voltages (&gt;1000 V) induce both thermal and nonthermal ablation mechanisms. This <i>in silico</i> model offers valuable insights into stent-related factors affecting IRE outcomes, reducing the need for extensive animal experiments.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.29457792
Primary Topic
DNA Repair Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mathematical modeling of the effect of stent construction during endoluminal IRE for recanalization of an occluded metal stent

Figshare
DNA Repair Mechanisms
article

Mathematical modeling of the effect of stent construction during endoluminal IRE for recanalization of an occluded metal stent

article en

Abstract

Intraluminal irreversible electroporation (IRE) can be used for recanalizing occluded metal stents. However, optimal IRE parameters for consistent effects across different stent designs remain unclear. The aim of this study was to simulate the process of stent recanalization <i>in silico</i> by employing finite element analysis. A virtual model of an occluded biliary stent with an experimental 3-electrode IRE catheter was developed. Electric field distribution, temperature changes, and potential ablation volumes were simulated across various parameters: IRE voltage (300 − 1300 V), stent wire width (0.1 − 0.5 mm) and stent mesh size (0.7 − 5.58 mm). Simulations incorporated five representative stent types commonly used in clinical practice. 685 unique simulations were conducted, analyzing 1162 unique values. Higher voltages generally led to larger ablation zones and increased temperatures. Thinner stent wires and larger mesh sizes also increased the extent of ablation zone. While in-stent ablation was largely independent of stent design, out-of-stent ablation was significantly impacted by mesh size and tissue thickness between the stent and irreversible electroporation electrodes. Voltages above 1000 V produced significant thermal effects, with substantial volumes of tissue heated above 50 °C. Specific stent designs exhibited variations in maximum temperature (72.1 − 83.1 °C) and ablation volume (8.7 − 14.7 mm<sup>3</sup>). Tailored IRE protocols for different stent designs are required due to differences in in- and out-stent ablation volumes. High voltages (&gt;1000 V) induce both thermal and nonthermal ablation mechanisms. This <i>in silico</i> model offers valuable insights into stent-related factors affecting IRE outcomes, reducing the need for extensive animal experiments.

Figshare
Openalex Percentile: Top 53%
DNA Repair Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.