Field evaluation of low-cost particulate matter (PM) sensor instruments in indoor and outdoor environments: A university lecture hall and urban southeastern United States

The increasing use of low-cost particulate matter (PM) sensors for air quality monitoring highlights the importance of understanding their performance across different environments. This study evaluated the performance of three low-cost sensor instruments—PurpleAir Plantower PMS5003 (PMS), Alphasense OPC-N3 (OPC-N3), and QuantAQ MODULAIR-PM—in indoor (university lecture hall) and outdoor (urban Atlanta) settings, focusing on measurements of PM<sub>1</sub>, PM<sub>2.5</sub>, and PM<sub>10</sub>. Reference data were obtained from a Scanning Mobility Particle Sizer (SMPS), an Aerosol Chemical Speciation Monitor (ACSM), and EPA monitoring sites. The PMS underreported PM<sub>10</sub> compared to the MODULAIR-PM when the coarse fraction exceeded 0.4. Regarding PM<sub>1</sub>, which accounted for the majority of PM<sub>2.5</sub>, PMS agreed with SMPS outdoors but underreported PM<sub>1</sub> by up to 60% at low concentrations (PM<sub>1</sub> &lt; 2.5 µg/m<sup>3</sup>), which was the majority of measurements in the lecture hall. An alternative correction factor improved PMS accuracy in clean environments but heavily depended on calibration (calibration factors varied from 2 to 7). The OPC-N3 struggled to detect particles &lt;350 nm but detected coarse particles missed by the PMS. The MODULAIR-PM combined strengths of both sensors, aligning with EPA references. While there were no consistent trends between relative humidity (RH) and low-cost instrument performance, we clearly demonstrated a correlation between aerosol liquid water content and low-cost sensor instrument bias. This study underscores the continuing need for developing and testing comprehensive and adjustable correction models that account for aerosol composition, particularly liquid water content. Our results emphasize the importance of considering particle size distribution, mass concentration, and chemical composition when selecting specific low-cost sensors to use and interpreting the corresponding data. Copyright © 2025 American Association for Aerosol Research

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.29038997.v1
Primary Topic
Space exploration and regulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Field evaluation of low-cost particulate matter (PM) sensor instruments in indoor and outdoor environments: A university lecture hall and urban southeastern United States

Figshare
Space exploration and regulation
article

Field evaluation of low-cost particulate matter (PM) sensor instruments in indoor and outdoor environments: A university lecture hall and urban southeastern United States

article en

Abstract

The increasing use of low-cost particulate matter (PM) sensors for air quality monitoring highlights the importance of understanding their performance across different environments. This study evaluated the performance of three low-cost sensor instruments—PurpleAir Plantower PMS5003 (PMS), Alphasense OPC-N3 (OPC-N3), and QuantAQ MODULAIR-PM—in indoor (university lecture hall) and outdoor (urban Atlanta) settings, focusing on measurements of PM<sub>1</sub>, PM<sub>2.5</sub>, and PM<sub>10</sub>. Reference data were obtained from a Scanning Mobility Particle Sizer (SMPS), an Aerosol Chemical Speciation Monitor (ACSM), and EPA monitoring sites. The PMS underreported PM<sub>10</sub> compared to the MODULAIR-PM when the coarse fraction exceeded 0.4. Regarding PM<sub>1</sub>, which accounted for the majority of PM<sub>2.5</sub>, PMS agreed with SMPS outdoors but underreported PM<sub>1</sub> by up to 60% at low concentrations (PM<sub>1</sub> &lt; 2.5 µg/m<sup>3</sup>), which was the majority of measurements in the lecture hall. An alternative correction factor improved PMS accuracy in clean environments but heavily depended on calibration (calibration factors varied from 2 to 7). The OPC-N3 struggled to detect particles &lt;350 nm but detected coarse particles missed by the PMS. The MODULAIR-PM combined strengths of both sensors, aligning with EPA references. While there were no consistent trends between relative humidity (RH) and low-cost instrument performance, we clearly demonstrated a correlation between aerosol liquid water content and low-cost sensor instrument bias. This study underscores the continuing need for developing and testing comprehensive and adjustable correction models that account for aerosol composition, particularly liquid water content. Our results emphasize the importance of considering particle size distribution, mass concentration, and chemical composition when selecting specific low-cost sensors to use and interpreting the corresponding data. Copyright © 2025 American Association for Aerosol Research

Figshare
Sustainable cities and communities
Openalex Percentile: Top 61%
Space exploration and regulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Field evaluation of low-cost particulate matter (PM) sensor instruments in indoor and outdoor environments: A university lecture hall and urban southeastern United States · Figshare (2025) | TGRS Research Map | TGRS