ANALYSIS OF POWER QUALITY DISTURBANCE DUE TO VOLTAGE SAG ON 33/11 KV NETWORK WITH DIFFERENT TRANSFORMER CONFIGURATION

This paper investigates the impact of voltage sags on power quality in a 33/11 kV distribution network by analyzing the behavior of different transformer configurations under various fault conditions. Voltage sag, a critical power quality disturbance, affects industrial performance and equipment reliability. Using MATLAB/Simulink, the 33/11 kV network supplying Shakti Nagar (MPPTCL) was modeled and subjected to different types of faults (SLG, DLG, DL, and 3-Φ). Simulation results were analyzed across three transformer configurations—Yg-Yg, Yg-Δ11, and Yg-Y. The performance of each configuration was compared using RMS voltage drop and voltage sag indices. The study concludes that transformer connection significantly influences the severity of voltage sag. The Yg-Y configuration offered the most stable response under SLG fault, while Yg-Δ11 performed better under DL and DLG faults.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-07-15
DOI
https://doi.org/10.5281/zenodo.16752054
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALYSIS OF POWER QUALITY DISTURBANCE DUE TO VOLTAGE SAG ON 33/11 KV NETWORK WITH DIFFERENT TRANSFORMER CONFIGURATION

Zenodo (CERN European Organization for Nuclear Research)
Power Quality and Harmonics
article

ANALYSIS OF POWER QUALITY DISTURBANCE DUE TO VOLTAGE SAG ON 33/11 KV NETWORK WITH DIFFERENT TRANSFORMER CONFIGURATION

article en

Abstract

This paper investigates the impact of voltage sags on power quality in a 33/11 kV distribution network by analyzing the behavior of different transformer configurations under various fault conditions. Voltage sag, a critical power quality disturbance, affects industrial performance and equipment reliability. Using MATLAB/Simulink, the 33/11 kV network supplying Shakti Nagar (MPPTCL) was modeled and subjected to different types of faults (SLG, DLG, DL, and 3-Φ). Simulation results were analyzed across three transformer configurations—Yg-Yg, Yg-Δ11, and Yg-Y. The performance of each configuration was compared using RMS voltage drop and voltage sag indices. The study concludes that transformer connection significantly influences the severity of voltage sag. The Yg-Y configuration offered the most stable response under SLG fault, while Yg-Δ11 performed better under DL and DLG faults.

Zenodo (CERN European Organization for Nuclear Research)
Maharaja Ranjit Singh Punjab Technical University (IN)
Affordable and clean energy
Openalex Percentile: Top 55%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ANALYSIS OF POWER QUALITY DISTURBANCE DUE TO VOLTAGE SAG ON 33/11 KV NETWORK WITH DIFFERENT TRANSFORMER CONFIGURATION · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS