METHOD DEVELOPMENT AND VALIDATION FOR THE QUANTITATIVE ESTIMATION OF PIRFENIDONE IN BULK AND MARKETED FORMULATION AND STUDY OF ITS DEGRADATION BEHAVIOUR BY UV-SPECTROSCOPY

A simple, precise, robust, and stability-indicating UV spectroscopic method was developed for the determination of Pirfenidone in bulk &its formulation, and to monitor the Degradation behaviour of the drug as per ICH Guidelines. Pirfenidone exhibited a maximum absorbance at 311nm in 50 v/v ethanol, which was selected as the analytical wavelength. The calibration curve exhibited a good linear relationship in the concentration range of 4-24µg/ml with a correlation coefficient (r2) of 0.9983. Precision was evaluated through intraday, interday variations with % RSD within 2. The LOD and LOQ were found to be 0.78and 2.41µg/ml respectively. Accuracy was assessed through recovery and was in the range of 98-102%. The mean % assay was found to be 99.81.Degradation studies of Pirfenidone were well studied in all stress conditions, and the amount of degraded drug was calculated(1-3). The degradation products were monitored and characterized to understand the stability profile of Pirfenidone. This validated method can be readily applied for routine quality control analysis of Pirfenidone in bulk and pharmaceutical dosage forms.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-04-16
DOI
https://doi.org/10.5281/zenodo.15229315
Primary Topic
Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

METHOD DEVELOPMENT AND VALIDATION FOR THE QUANTITATIVE ESTIMATION OF PIRFENIDONE IN BULK AND MARKETED FORMULATION AND STUDY OF ITS DEGRADATION BEHAVIOUR BY UV-SPECTROSCOPY

Zenodo (CERN European Organization for Nuclear Research)
Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
article

METHOD DEVELOPMENT AND VALIDATION FOR THE QUANTITATIVE ESTIMATION OF PIRFENIDONE IN BULK AND MARKETED FORMULATION AND STUDY OF ITS DEGRADATION BEHAVIOUR BY UV-SPECTROSCOPY

article en

Abstract

A simple, precise, robust, and stability-indicating UV spectroscopic method was developed for the determination of Pirfenidone in bulk &its formulation, and to monitor the Degradation behaviour of the drug as per ICH Guidelines. Pirfenidone exhibited a maximum absorbance at 311nm in 50 v/v ethanol, which was selected as the analytical wavelength. The calibration curve exhibited a good linear relationship in the concentration range of 4-24µg/ml with a correlation coefficient (r2) of 0.9983. Precision was evaluated through intraday, interday variations with % RSD within 2. The LOD and LOQ were found to be 0.78and 2.41µg/ml respectively. Accuracy was assessed through recovery and was in the range of 98-102%. The mean % assay was found to be 99.81.Degradation studies of Pirfenidone were well studied in all stress conditions, and the amount of degraded drug was calculated(1-3). The degradation products were monitored and characterized to understand the stability profile of Pirfenidone. This validated method can be readily applied for routine quality control analysis of Pirfenidone in bulk and pharmaceutical dosage forms.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 36%
Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.