Monitoring spontaneous breathing during apnea testing with electrical impedance tomography

Abstract: The apnea test (AT) is a critical procedure in the determination of brain death (BD), with the detection of spontaneous breathing efforts serving as a key criterion. However, the reliance on visual observation alone for this assessment can pose challenges in detecting subtle respiratory movements. This case report presents the integration of electrical impedance tomography (EIT) as an adjunctive monitoring tool during the AT in a BD patient, demonstrating its potential to provide real-time visualization of ventilation distribution and detect changes in lung volume. The findings suggest that EIT could enhance the sensitivity and accuracy of detecting spontaneous breathing efforts, offering additional insights into respiratory status of the patient.

Institutions

Publication Details

Journal
Repository of Futwangen University of Applied Sciences (Furtwangen University)
Published
2024-12-01
DOI
https://doi.org/10.5281/zenodo.14277323
Primary Topic
Organ Donation and Transplantation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring spontaneous breathing during apnea testing with electrical impedance tomography

Repository of Futwangen University of Applied Sciences (Furtwangen University)
Organ Donation and Transplantation
article

Monitoring spontaneous breathing during apnea testing with electrical impedance tomography

article en

Abstract

Abstract: The apnea test (AT) is a critical procedure in the determination of brain death (BD), with the detection of spontaneous breathing efforts serving as a key criterion. However, the reliance on visual observation alone for this assessment can pose challenges in detecting subtle respiratory movements. This case report presents the integration of electrical impedance tomography (EIT) as an adjunctive monitoring tool during the AT in a BD patient, demonstrating its potential to provide real-time visualization of ventilation distribution and detect changes in lung volume. The findings suggest that EIT could enhance the sensitivity and accuracy of detecting spontaneous breathing efforts, offering additional insights into respiratory status of the patient.

Repository of Futwangen University of Applied Sciences (Furtwangen University)
Semmelweis University (HU), University of Freiburg (DE), Jahn Ferenc Dél-Pesti Kórház és Rendelőintézet (HU), Furtwangen University (DE)
Szegedi Tudományegyetem, Horizon 2020 Framework Programme
Good health and well-being
Openalex Percentile: Top 45%
Organ Donation and Transplantation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.