Method Development and Method Validation of Daprodustat - Using Reverse phase High Performance Liquid Chromatography Method

Aim: Daprodustat in pharmaceutical dosage forms has been previously analyzed quantitatively using reverse-phase high-performance liquid chromatography (RP-HPLC) approach that was easy to use, quick, accurate, sensitive, and repeatable. Materials and methods: Daprodustat was separated chromatographically using a Waters Alliance e2695 system and a Waters X-Terra RP-18 column (150x4.6mm, 3.5µ). The mobile phase was made up of 50% v/v ACN and HSA pH-2.5/OPA. Photodiode array detector was operated at room temperature is utilized to detect absorption at 235 nanometers while the flowrate was fixed at 1.0 ml/minute. Results: For Daprodustat, it was guaranteed that the theoretical plate count and tailing factor would be at least 2000 and 2, respectively. The percentage of standard deviation for peak regions consistently below 2.0 in all measurements. Conclusion: The proposed approach was validated in compliance with ICH requirements, and it was found to be an easy-to-use, reasonably priced, appropriate, precise, accurate, and reliable tool for Daprodustat quantitative evaluation.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-04-29
DOI
https://doi.org/10.5281/zenodo.15303481
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method Development and Method Validation of Daprodustat - Using Reverse phase High Performance Liquid Chromatography Method

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

Method Development and Method Validation of Daprodustat - Using Reverse phase High Performance Liquid Chromatography Method

article en

Abstract

Aim: Daprodustat in pharmaceutical dosage forms has been previously analyzed quantitatively using reverse-phase high-performance liquid chromatography (RP-HPLC) approach that was easy to use, quick, accurate, sensitive, and repeatable. Materials and methods: Daprodustat was separated chromatographically using a Waters Alliance e2695 system and a Waters X-Terra RP-18 column (150x4.6mm, 3.5µ). The mobile phase was made up of 50% v/v ACN and HSA pH-2.5/OPA. Photodiode array detector was operated at room temperature is utilized to detect absorption at 235 nanometers while the flowrate was fixed at 1.0 ml/minute. Results: For Daprodustat, it was guaranteed that the theoretical plate count and tailing factor would be at least 2000 and 2, respectively. The percentage of standard deviation for peak regions consistently below 2.0 in all measurements. Conclusion: The proposed approach was validated in compliance with ICH requirements, and it was found to be an easy-to-use, reasonably priced, appropriate, precise, accurate, and reliable tool for Daprodustat quantitative evaluation.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 52%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.