In vitro test setup for continuous evaluation of oxygenators for extracorporeal circulation

Abstract: Extracorporeal Membrane Oxygenation (ECMO) is essential for treating severe pulmonary and cardiac failure but is associated with significant risks, including mechanical failures and clot formation. This study presents an in vitro test setup for the continuous evaluation of ECMO oxygenators. Utilizing porcine blood and hollow glass microbeads to induce clotting, the setup measures key parameters such as pressure difference, hemolysis index, and gas transfer rates. Results indicate increased pressure difference and hemolysis, with stable oxygen transfer but declining carbon dioxide transfer over time, highlighting the impact of clot formation. The setup offers a reliable framework for oxygenator performance evaluation.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-01
DOI
https://doi.org/10.5281/zenodo.14278601
Primary Topic
Space Exploration and Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vitro test setup for continuous evaluation of oxygenators for extracorporeal circulation

Zenodo (CERN European Organization for Nuclear Research)
Space Exploration and Technology
article

In vitro test setup for continuous evaluation of oxygenators for extracorporeal circulation

article en

Abstract

Abstract: Extracorporeal Membrane Oxygenation (ECMO) is essential for treating severe pulmonary and cardiac failure but is associated with significant risks, including mechanical failures and clot formation. This study presents an in vitro test setup for the continuous evaluation of ECMO oxygenators. Utilizing porcine blood and hollow glass microbeads to induce clotting, the setup measures key parameters such as pressure difference, hemolysis index, and gas transfer rates. Results indicate increased pressure difference and hemolysis, with stable oxygen transfer but declining carbon dioxide transfer over time, highlighting the impact of clot formation. The setup offers a reliable framework for oxygenator performance evaluation.

Zenodo (CERN European Organization for Nuclear Research)
Technische Universität Dresden (DE)
Openalex Percentile: Top 33%
Space Exploration and Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.