Toward a Standarized Robotics-Enabled Execution of Muscle Shortening Maneuver

The Muscle Shortening Maneuver (MSM) is a rehabilitation technique applicable to several pathological conditions. This approach involves passively elongating and shortening the targeted muscle group in the affected limb. Current rehabilitation centers implement these passive motions manually or through external actuators without feedback control, which can diminish the effectiveness and standardization of the MSM. In this research, we designed and developed a mechatronic device capable of accurately delivering the required motion to the upper limb. First, the motion parameters were extracted from therapy sessions conducted by experienced therapists at the rehabilitation clinic. Based on this information, the actuator was selected, and an experimental setup was developed. Sliding mode control with a sliding perturbation observer was implemented for precise motion control. Experiments were conducted on one healthy participant to validate the performance of the developed device. The results, although preliminary, suggest that our system is capable of producing oscillation within the desired motion range

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-10-25
DOI
https://doi.org/10.5281/zenodo.14731040
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Toward a Standarized Robotics-Enabled Execution of Muscle Shortening Maneuver

Zenodo (CERN European Organization for Nuclear Research)
Prosthetics and Rehabilitation Robotics
article

Toward a Standarized Robotics-Enabled Execution of Muscle Shortening Maneuver

article en

Abstract

The Muscle Shortening Maneuver (MSM) is a rehabilitation technique applicable to several pathological conditions. This approach involves passively elongating and shortening the targeted muscle group in the affected limb. Current rehabilitation centers implement these passive motions manually or through external actuators without feedback control, which can diminish the effectiveness and standardization of the MSM. In this research, we designed and developed a mechatronic device capable of accurately delivering the required motion to the upper limb. First, the motion parameters were extracted from therapy sessions conducted by experienced therapists at the rehabilitation clinic. Based on this information, the actuator was selected, and an experimental setup was developed. Sliding mode control with a sliding perturbation observer was implemented for precise motion control. Experiments were conducted on one healthy participant to validate the performance of the developed device. The results, although preliminary, suggest that our system is capable of producing oscillation within the desired motion range

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Openalex Percentile: Top 66%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.