DISTANCE RELAY PROTECTION OF AN 11 kV DISTRIBUTION SYSTEM PERFORMANCE ENHANCEMENT USING MICROPROCESSORS

Transmission and distribution lines are protected against fault in power network using protection methods and distance relays. This work focused on enhancing the speed of isolating defective circuits from the network by employing a microprocessor to minimize tripping time of the relay. The microprocessor was programmed with the help of information from network-wide fault research. Through the application of Power System Computer Aided Design (PSCAD) software simulations, the designed system's operating time for a line-to-line (LLG) fault between lines ABG occurring at 35 km on the tested line with a fault impedance of 5 Ω was 5.4 ms, while the old system, which was the conventional distance relay system without a microprocessor, had an operating time of 15 ms. In actuality, it was discovered that the new protective mechanism utilizing the microprocessor increased the average operating speed of the distance protection scheme from 6.144 ms to 4.390 ms, leading to boosting around 28.5% in the operating speed or speed of isolating the malfunctioning circuit. Also, the average tripping accuracy was improved from 67.5% to 100% for the developed system which shows 48% increase in accuracy.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-17
DOI
https://doi.org/10.5281/zenodo.14521505
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DISTANCE RELAY PROTECTION OF AN 11 kV DISTRIBUTION SYSTEM PERFORMANCE ENHANCEMENT USING MICROPROCESSORS

Zenodo (CERN European Organization for Nuclear Research)
Power Systems Fault Detection
article

DISTANCE RELAY PROTECTION OF AN 11 kV DISTRIBUTION SYSTEM PERFORMANCE ENHANCEMENT USING MICROPROCESSORS

article en

Abstract

Transmission and distribution lines are protected against fault in power network using protection methods and distance relays. This work focused on enhancing the speed of isolating defective circuits from the network by employing a microprocessor to minimize tripping time of the relay. The microprocessor was programmed with the help of information from network-wide fault research. Through the application of Power System Computer Aided Design (PSCAD) software simulations, the designed system's operating time for a line-to-line (LLG) fault between lines ABG occurring at 35 km on the tested line with a fault impedance of 5 Ω was 5.4 ms, while the old system, which was the conventional distance relay system without a microprocessor, had an operating time of 15 ms. In actuality, it was discovered that the new protective mechanism utilizing the microprocessor increased the average operating speed of the distance protection scheme from 6.144 ms to 4.390 ms, leading to boosting around 28.5% in the operating speed or speed of isolating the malfunctioning circuit. Also, the average tripping accuracy was improved from 67.5% to 100% for the developed system which shows 48% increase in accuracy.

Zenodo (CERN European Organization for Nuclear Research)
Université Ouaga II (BF), Michael Okpara University of Agriculture (NG)
Affordable and clean energy
Openalex Percentile: Top 56%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.