Mitigation Of Voltage Sag With Transformerless Dvr Based On Reduced Switch Count Multilevel Inverter

Voltage sag is widely regarded as one of the most critical power quality issues in power systems. Dynamic Voltage Restorers (DVRs) offer a costeffective solution to protect sensitive loads from such disturbances. Further reductions in cost, as well as improvements in reliability and efficiency, can be achieved by removing the injection transformer. This paper presents a transformer less DVR design based on a T-type multilevel inverter. Without an injection transformer, the proposed DVR is more economical, lighter, and more compact. The DVR controller uses d- q transformation, and MATLAB/SIMULINK is employed to generate the simulation results

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-11-21
DOI
https://doi.org/10.5281/zenodo.14198141
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigation Of Voltage Sag With Transformerless Dvr Based On Reduced Switch Count Multilevel Inverter

Zenodo (CERN European Organization for Nuclear Research)
Power Quality and Harmonics
article

Mitigation Of Voltage Sag With Transformerless Dvr Based On Reduced Switch Count Multilevel Inverter

article en

Abstract

Voltage sag is widely regarded as one of the most critical power quality issues in power systems. Dynamic Voltage Restorers (DVRs) offer a costeffective solution to protect sensitive loads from such disturbances. Further reductions in cost, as well as improvements in reliability and efficiency, can be achieved by removing the injection transformer. This paper presents a transformer less DVR design based on a T-type multilevel inverter. Without an injection transformer, the proposed DVR is more economical, lighter, and more compact. The DVR controller uses d- q transformation, and MATLAB/SIMULINK is employed to generate the simulation results

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 66%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mitigation Of Voltage Sag With Transformerless Dvr Based On Reduced Switch Count Multilevel Inverter · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS