A Novel Validated Uplc Method for The Determination of Prucalopride Succinate in Solid Dosage Form

The objective of the current study was to develop a novel technique, simple, precise, rapid, reproducible and selective UPLC method for the estimation of Prucalopride Succinate in bulk and tablet dosage form. Estimation was achieved by C18 (50mm×3mm×1.7µ) column using Potassium dihydrogen ortho phosphate and Methanol, Ratio 60:40 %w/w at ambient temperature. Flow Rate was 0.8ml/min, injection volume 2 µl and detectable wavelength at 225nm. The retention time for Prucalopride succinate was 0.61 minutes. The method was validated for specificity, linearity, precision, accuracy; robustness .The linearity of the proposed method was at the range of 50-150µg/ ml of Prucalopride succinate with a correlation coefficient of 0.9999. The precision (relative standard deviation – RSD) of six samples was 0.5066%. The accuracy (recovery) was 100.07 % and 100.19 %.and 99.93%.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-09
DOI
https://doi.org/10.5281/zenodo.14332878
Primary Topic
Oceanographic and Atmospheric Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Validated Uplc Method for The Determination of Prucalopride Succinate in Solid Dosage Form

Zenodo (CERN European Organization for Nuclear Research)
Oceanographic and Atmospheric Processes
article

A Novel Validated Uplc Method for The Determination of Prucalopride Succinate in Solid Dosage Form

article en

Abstract

The objective of the current study was to develop a novel technique, simple, precise, rapid, reproducible and selective UPLC method for the estimation of Prucalopride Succinate in bulk and tablet dosage form. Estimation was achieved by C18 (50mm×3mm×1.7µ) column using Potassium dihydrogen ortho phosphate and Methanol, Ratio 60:40 %w/w at ambient temperature. Flow Rate was 0.8ml/min, injection volume 2 µl and detectable wavelength at 225nm. The retention time for Prucalopride succinate was 0.61 minutes. The method was validated for specificity, linearity, precision, accuracy; robustness .The linearity of the proposed method was at the range of 50-150µg/ ml of Prucalopride succinate with a correlation coefficient of 0.9999. The precision (relative standard deviation – RSD) of six samples was 0.5066%. The accuracy (recovery) was 100.07 % and 100.19 %.and 99.93%.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 55%
Oceanographic and Atmospheric Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.