Analytical Method Development, Validation Of Pitolisant Drug By Using RP-HPLC Method

Attempts to develop a robust RP-HPLC method for estimating Pitolisant in tablet form were made using an Agilent (S.K) Gradient System with a UV Detector. The C18 column employed measured 250 mm x 4.6 mm with a particle size of 5 μm. The mobile phase consisted of methanol and 0.1% water with OPA in a 45%:55% v/v ratio. Detection was carried out at a wavelength of 266 nm with a flow rate of 0.8 ml/min. The retention times for Pitolisant were found to be 3.934 and 4.627 minutes. The method was validated in accordance with ICH guidelines, demonstrating linearity over the range of 5-25 μg/ml, and precision with a value of 98.95%. The method's limit of detection (LOD) was determined to be 0.1004 μg/ml, and the limit of quantitation (LOQ) was 0.304 μg/ml. Accuracy and recovery percentages were within the 98-102% range. Additionally, the system's robustness met the criteria specified by the ICH guidelines. Therefore, the developed method is simple, accurate, precise, economical, and reproducible, making it suitable for routine quality control analysis of Pitolisant in both bulk drugs and formulations.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-08-08
DOI
https://doi.org/10.5281/zenodo.13273665
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Method Development, Validation Of Pitolisant Drug By Using RP-HPLC Method

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

Analytical Method Development, Validation Of Pitolisant Drug By Using RP-HPLC Method

article en

Abstract

Attempts to develop a robust RP-HPLC method for estimating Pitolisant in tablet form were made using an Agilent (S.K) Gradient System with a UV Detector. The C18 column employed measured 250 mm x 4.6 mm with a particle size of 5 μm. The mobile phase consisted of methanol and 0.1% water with OPA in a 45%:55% v/v ratio. Detection was carried out at a wavelength of 266 nm with a flow rate of 0.8 ml/min. The retention times for Pitolisant were found to be 3.934 and 4.627 minutes. The method was validated in accordance with ICH guidelines, demonstrating linearity over the range of 5-25 μg/ml, and precision with a value of 98.95%. The method's limit of detection (LOD) was determined to be 0.1004 μg/ml, and the limit of quantitation (LOQ) was 0.304 μg/ml. Accuracy and recovery percentages were within the 98-102% range. Additionally, the system's robustness met the criteria specified by the ICH guidelines. Therefore, the developed method is simple, accurate, precise, economical, and reproducible, making it suitable for routine quality control analysis of Pitolisant in both bulk drugs and formulations.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 64%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analytical Method Development, Validation Of Pitolisant Drug By Using RP-HPLC Method · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS