Development and Validation of HPLC Method for Determination of an API in Presence of its Degradation Products

The present study describes the development and validation of HPLC (HILIC) method for determination of an Imeglimin in presence of its degradation products. The proposed HPLC method utilizes a new HILIC for the determination of Imeglimin. The separation was achieved by using ZIC-HILIC (5µm; 150 x 4.6 mm ID.column by using solvent A; 15mM ammonium acetate solvent B; acetonitrile (50:50, v/v) as mobile phase with the flow rate of 1ml/min. Where detection was carried out by UV detector (SPD-10AVP) at 230nm. The retention time was found to be 5.138min. The described method was linear over the range of 1.56 –50 µg/ml. 1.56 –50 µg/ml . The mean regression equation was found to be y= 336299x + 344398 , R 2 = 0.9997. The precision, ruggedness, accuracy, repeatability, robustness values were also within the prescribed limits. Imeglimin was exposed to acidic, basic, oxidative, thermal, photo degradation and stressed samples were analysed by the proposed method. Chromatographic peak purity results indicated the absence of co-eluting peaks with the main peak of Imeglimin, which demonstrated the specificity of method for estimation of Imeglimin in presence of degradation products. The proposed method can be used for routine analysis of Imeglimin.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-06-23
DOI
https://doi.org/10.5281/zenodo.15718181
Primary Topic
Species Distribution and Climate Change
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of HPLC Method for Determination of an API in Presence of its Degradation Products

Zenodo (CERN European Organization for Nuclear Research)
Species Distribution and Climate Change
article

Development and Validation of HPLC Method for Determination of an API in Presence of its Degradation Products

article en

Abstract

The present study describes the development and validation of HPLC (HILIC) method for determination of an Imeglimin in presence of its degradation products. The proposed HPLC method utilizes a new HILIC for the determination of Imeglimin. The separation was achieved by using ZIC-HILIC (5µm; 150 x 4.6 mm ID.column by using solvent A; 15mM ammonium acetate solvent B; acetonitrile (50:50, v/v) as mobile phase with the flow rate of 1ml/min. Where detection was carried out by UV detector (SPD-10AVP) at 230nm. The retention time was found to be 5.138min. The described method was linear over the range of 1.56 –50 µg/ml. 1.56 –50 µg/ml . The mean regression equation was found to be y= 336299x + 344398 , R 2 = 0.9997. The precision, ruggedness, accuracy, repeatability, robustness values were also within the prescribed limits. Imeglimin was exposed to acidic, basic, oxidative, thermal, photo degradation and stressed samples were analysed by the proposed method. Chromatographic peak purity results indicated the absence of co-eluting peaks with the main peak of Imeglimin, which demonstrated the specificity of method for estimation of Imeglimin in presence of degradation products. The proposed method can be used for routine analysis of Imeglimin.

Zenodo (CERN European Organization for Nuclear Research)
Clean water and sanitation
Openalex Percentile: Top 40%
Species Distribution and Climate Change
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.