To Evaluate Safety on Direct Trocar Insertion

Introduction: Direct trocar insertion is a minimally invasive surgical technique used to insert instruments into the body through small incisions, to reducing recovery time and minimizing tissue damage. Aims and Objective: To develop and refine techniques for direct trocar insertion, enhancing precision and safety, to minimizing complications, and improving patient outcomes through innovative research and its clinical application. Method: A study was conducted with 45 patients undergoing laparoscopic surgery. A 10-mm trocar was directly inserted into the peritoneal cavity without prior pneumoperitoneum. Patients were positioned supine, and a small infraumbilical incision was made. The trocar was inserted at a 90-degree angle using controlled force. Entry was confirmed by visualizing the peritoneal cavity with a laparoscope. Patient outcomes, insertion time, and complications were recorded. No major complications occurred, and average insertion time was 30 seconds. Results: The study investigates the efficacy of direct trocar insertion (DTI) in laparoscopic surgeries. Results show that DTI reduces the risk of visceral and vascular injuries compared to the Veress needle technique. Patients undergoing DTI experienced shorter setup times and fewer postoperative complications. The findings suggest that DTI is a safer and more efficient method for establishing pneumoperitoneum, enhancing overall surgical outcomes. Conclusion: The study investigates the efficacy of direct trocar insertion (DTI) in laparoscopic surgeries. Results show that DTI reduces the risk of visceral and vascular injuries compared to the Veress needle technique. Patients undergoing DTI experienced shorter setup times and fewer postoperative complications. The findings suggest that DTI is a safer and more efficient method for establishing pneumoperitoneum, enhancing overall surgical outcomes.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-11-26
DOI
https://doi.org/10.5281/zenodo.14590883
Primary Topic
Minimally Invasive Surgical Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

To Evaluate Safety on Direct Trocar Insertion

Zenodo (CERN European Organization for Nuclear Research)
Minimally Invasive Surgical Techniques
article

To Evaluate Safety on Direct Trocar Insertion

article en

Abstract

Introduction: Direct trocar insertion is a minimally invasive surgical technique used to insert instruments into the body through small incisions, to reducing recovery time and minimizing tissue damage. Aims and Objective: To develop and refine techniques for direct trocar insertion, enhancing precision and safety, to minimizing complications, and improving patient outcomes through innovative research and its clinical application. Method: A study was conducted with 45 patients undergoing laparoscopic surgery. A 10-mm trocar was directly inserted into the peritoneal cavity without prior pneumoperitoneum. Patients were positioned supine, and a small infraumbilical incision was made. The trocar was inserted at a 90-degree angle using controlled force. Entry was confirmed by visualizing the peritoneal cavity with a laparoscope. Patient outcomes, insertion time, and complications were recorded. No major complications occurred, and average insertion time was 30 seconds. Results: The study investigates the efficacy of direct trocar insertion (DTI) in laparoscopic surgeries. Results show that DTI reduces the risk of visceral and vascular injuries compared to the Veress needle technique. Patients undergoing DTI experienced shorter setup times and fewer postoperative complications. The findings suggest that DTI is a safer and more efficient method for establishing pneumoperitoneum, enhancing overall surgical outcomes. Conclusion: The study investigates the efficacy of direct trocar insertion (DTI) in laparoscopic surgeries. Results show that DTI reduces the risk of visceral and vascular injuries compared to the Veress needle technique. Patients undergoing DTI experienced shorter setup times and fewer postoperative complications. The findings suggest that DTI is a safer and more efficient method for establishing pneumoperitoneum, enhancing overall surgical outcomes.

Zenodo (CERN European Organization for Nuclear Research)
Assam Medical College (IN)
Openalex Percentile: Top 44%
Minimally Invasive Surgical Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

To Evaluate Safety on Direct Trocar Insertion · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS