D3.2 Cell characterization and combination with thermal management system technology

This report contains a summary of the work carried out in Task 3.1a, T3.1b and T3.5 within WP3. Specifically, these tasks focus on the electrical and thermal characterisation of the initial candidate battery cells, including modelling of their performance to feed BMS development activities in WP4, as well as the initial design of the cooling system for the battery pack refrigeration. Within the execution of these tasks, it has been found that the performance of the cells was in-line with manufacturer specifications. Additional experimental data has fed the electrochemical and equivalent circuit to reach precision below 30 mV. Three different electrochemical models have been used to reproduce the cell behaviour. The validation process has shown the NTGK model to be the most suitable for the goals of the project. Five different discharge rates have been simulated: 0.05, 0.33, 0.5, 1 and 2 C. The maximum heat generated corresponds to the 2C rate discharge, with a value of 41 kW/m3, which is the most important information for the future design of the cooling circuit. A linear fit has also been obtained relating the total heat generated and the discharge rate. In terms of electrical (voltage) response, a 2-RC-equivalent circuit model (ECM) has been developed. The parameters have been calculated based on the HPPC-measurement data (current pulse at different SoC-steps and operation points) by a least-squares algorithm. This resulted in a set of model parameters for every operation point (T, SoC, I), which can then be used to simulate the cell’s electrical response at any driving profile. To assess the model accuracy, a WLTC profile was simulated for a representative cell, which showed satisfying results considering the 30 mV error window. In contrast, the ECM cannot predict the temperature evolution of the cell as accurate as the electrochemical model, which leads to the conclusion, that both models will be combined with their respective advantages to build an overall modelling approach with high accuracy. The TMS can be characterised by a top and bottom cooling design. With aluminium fins in between the cells a homogeneous temperature distribution can be achieved within the BP. Open cell aluminium foam can improve the thermal conductivity to fulfil the project requirements from the thermal standpoint.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-05-26
DOI
https://doi.org/10.5281/zenodo.15516050
Primary Topic
Toxoplasma gondii Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

D3.2 Cell characterization and combination with thermal management system technology

Zenodo (CERN European Organization for Nuclear Research)
Toxoplasma gondii Research Studies
article

D3.2 Cell characterization and combination with thermal management system technology

article en

Abstract

This report contains a summary of the work carried out in Task 3.1a, T3.1b and T3.5 within WP3. Specifically, these tasks focus on the electrical and thermal characterisation of the initial candidate battery cells, including modelling of their performance to feed BMS development activities in WP4, as well as the initial design of the cooling system for the battery pack refrigeration. Within the execution of these tasks, it has been found that the performance of the cells was in-line with manufacturer specifications. Additional experimental data has fed the electrochemical and equivalent circuit to reach precision below 30 mV. Three different electrochemical models have been used to reproduce the cell behaviour. The validation process has shown the NTGK model to be the most suitable for the goals of the project. Five different discharge rates have been simulated: 0.05, 0.33, 0.5, 1 and 2 C. The maximum heat generated corresponds to the 2C rate discharge, with a value of 41 kW/m3, which is the most important information for the future design of the cooling circuit. A linear fit has also been obtained relating the total heat generated and the discharge rate. In terms of electrical (voltage) response, a 2-RC-equivalent circuit model (ECM) has been developed. The parameters have been calculated based on the HPPC-measurement data (current pulse at different SoC-steps and operation points) by a least-squares algorithm. This resulted in a set of model parameters for every operation point (T, SoC, I), which can then be used to simulate the cell’s electrical response at any driving profile. To assess the model accuracy, a WLTC profile was simulated for a representative cell, which showed satisfying results considering the 30 mV error window. In contrast, the ECM cannot predict the temperature evolution of the cell as accurate as the electrochemical model, which leads to the conclusion, that both models will be combined with their respective advantages to build an overall modelling approach with high accuracy. The TMS can be characterised by a top and bottom cooling design. With aluminium fins in between the cells a homogeneous temperature distribution can be achieved within the BP. Open cell aluminium foam can improve the thermal conductivity to fulfil the project requirements from the thermal standpoint.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 48%
Toxoplasma gondii Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.