Marginal gap of printed, milled, and heat-pressed two-piece polyetheretherketone abutments before and after thermal cycling, and their pull-off bond strength after thermal cycling.

Purpose To evaluate the marginal gap of two-piece polyetheretherketone (PEEK) abutments fabricated with different methods, before and after thermal cycling, while also focusing on their pull-off bond strength. Materials And Methods A two-piece abutment was virtually designed after digitizing a titanium-base (Ti-base) abutment. This design was used to fabricate printed (P-PEEK), milled (M-PEEK), and heat-pressed (HP-PEEK) PEEK abutments (n = 8). The marginal gaps of all abutments were evaluated under a stereomicroscope (15 points on each side, ×40 magnification), before and after thermal cycling (10,000 cycles, 5°C-55°C). Then, all abutments were subjected to a pull-off bond strength test. The marginal gap data were analyzed with a generalized linear model, while the pull-off bond strength data were analyzed with one-way analysis of variance and Tukey tests (α = 0.05). Results The marginal gaps were affected by the interaction between the fabrication method and aging condition, as well as by the fabrication method and aging condition (p ≤ 0.003). HP-PEEK abutments before thermal cycling had the lowest gap, whereas M-PEEK abutments after thermal cycling mostly had the highest (p ≤ 0.042). Thermal cycling increased the marginal gap of HP-PEEK (p < 0.001). M-PEEK had the lowest and HP-PEEK had the highest pull-off bond strength (p < 0.001). Most of the failures of P-PEEK and M-PEEK abutments were mixed. Conclusions The tested abutments had marginal gaps below the clinically acceptable threshold of 120 µm, both before and after thermal cycling. HP-PEEK abutments may be more resistant to dislodgment from the Ti-base abutments than P-PEEK and M-PEEK abutments.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-04-02
DOI
https://doi.org/10.48620/87695
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Marginal gap of printed, milled, and heat-pressed two-piece polyetheretherketone abutments before and after thermal cycling, and their pull-off bond strength after thermal cycling.

Open Access CRIS of the University of Bern
Dental Implant Techniques and Outcomes
article

Marginal gap of printed, milled, and heat-pressed two-piece polyetheretherketone abutments before and after thermal cycling, and their pull-off bond strength after thermal cycling.

article en

Abstract

Purpose To evaluate the marginal gap of two-piece polyetheretherketone (PEEK) abutments fabricated with different methods, before and after thermal cycling, while also focusing on their pull-off bond strength. Materials And Methods A two-piece abutment was virtually designed after digitizing a titanium-base (Ti-base) abutment. This design was used to fabricate printed (P-PEEK), milled (M-PEEK), and heat-pressed (HP-PEEK) PEEK abutments (n = 8). The marginal gaps of all abutments were evaluated under a stereomicroscope (15 points on each side, ×40 magnification), before and after thermal cycling (10,000 cycles, 5°C-55°C). Then, all abutments were subjected to a pull-off bond strength test. The marginal gap data were analyzed with a generalized linear model, while the pull-off bond strength data were analyzed with one-way analysis of variance and Tukey tests (α = 0.05). Results The marginal gaps were affected by the interaction between the fabrication method and aging condition, as well as by the fabrication method and aging condition (p ≤ 0.003). HP-PEEK abutments before thermal cycling had the lowest gap, whereas M-PEEK abutments after thermal cycling mostly had the highest (p ≤ 0.042). Thermal cycling increased the marginal gap of HP-PEEK (p < 0.001). M-PEEK had the lowest and HP-PEEK had the highest pull-off bond strength (p < 0.001). Most of the failures of P-PEEK and M-PEEK abutments were mixed. Conclusions The tested abutments had marginal gaps below the clinically acceptable threshold of 120 µm, both before and after thermal cycling. HP-PEEK abutments may be more resistant to dislodgment from the Ti-base abutments than P-PEEK and M-PEEK abutments.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 40%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.