45 degrees helical plates are a valid alternative to straight plates for treatment of proximal humeral shaft fractures

Helical plates used for proximal humeral shaft fracture fixation avoid the radial nerve distally as compared to straight plates. To investigate in a human cadaveric model the biomechanical competence of straight lateral plates versus 45 degrees helical plates used for fixation of proximal comminuted humeral shaft fractures, eight pairs of human cadaveric humeri were instrumented using either a long straight PHILOS plate (Group 1) or a 45 degrees helical plate (Group 2) for treatment of an unstable proximal humeral shaft fracture. All specimens were tested under non-destructive quasi-static loading in axial compression, internal and external rotation, and bending in four directions. Subsequently, progressively increasing cyclic loading in internal rotation was applied until failure and interfragmentary movements were monitored by motion tracking. Axial displacement (mm) was 3.13 +/- 0.31 in Group 1 and 2.60 +/- 0.42 in Group 2, p = 0.015. Flexion/extension deformation ( degrees ) in Group 1 and Group 2 was 0.56 +/- 0.42 and 0.43 +/- 0.23, p = 0.551. Varus/valgus deformation ( degrees ) was 6.39 +/- 0.44 in Group 1 and 5.13 +/- 0.87 in Group 2, p = 0.012. Shear (mm) and torsional ( degrees ) displacement were 5.36 +/- 0.76 and 17.75 +/- 1.06 in Group 1, and 5.03 +/- 0.46 and 16.79 +/- 1.36 in Group 2, p >/= 0.090. Cycles to catastrophic failure were 10000 +/- 1401 in Group 1 and 9082 +/- 1933 in Group 2, p = 0.708. From a biomechanical perspective, 45 degrees helical plating is associated with lower axial and varus/valgus displacement under axial loading and demonstrates comparable resistance to failure versus straight plating. Therefore, 45 degrees helical plates can be considered as a valid alternative to straight plates for treatment of proximal humeral shaft fractures.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2025-03-01
DOI
https://doi.org/10.5167/uzh-269283
Primary Topic
Species Distribution and Climate Change
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

45 degrees helical plates are a valid alternative to straight plates for treatment of proximal humeral shaft fractures

Zurich Open Repository and Archive (University of Zurich)
Species Distribution and Climate Change
article

45 degrees helical plates are a valid alternative to straight plates for treatment of proximal humeral shaft fractures

article en

Abstract

Helical plates used for proximal humeral shaft fracture fixation avoid the radial nerve distally as compared to straight plates. To investigate in a human cadaveric model the biomechanical competence of straight lateral plates versus 45 degrees helical plates used for fixation of proximal comminuted humeral shaft fractures, eight pairs of human cadaveric humeri were instrumented using either a long straight PHILOS plate (Group 1) or a 45 degrees helical plate (Group 2) for treatment of an unstable proximal humeral shaft fracture. All specimens were tested under non-destructive quasi-static loading in axial compression, internal and external rotation, and bending in four directions. Subsequently, progressively increasing cyclic loading in internal rotation was applied until failure and interfragmentary movements were monitored by motion tracking. Axial displacement (mm) was 3.13 +/- 0.31 in Group 1 and 2.60 +/- 0.42 in Group 2, p = 0.015. Flexion/extension deformation ( degrees ) in Group 1 and Group 2 was 0.56 +/- 0.42 and 0.43 +/- 0.23, p = 0.551. Varus/valgus deformation ( degrees ) was 6.39 +/- 0.44 in Group 1 and 5.13 +/- 0.87 in Group 2, p = 0.012. Shear (mm) and torsional ( degrees ) displacement were 5.36 +/- 0.76 and 17.75 +/- 1.06 in Group 1, and 5.03 +/- 0.46 and 16.79 +/- 1.36 in Group 2, p >/= 0.090. Cycles to catastrophic failure were 10000 +/- 1401 in Group 1 and 9082 +/- 1933 in Group 2, p = 0.708. From a biomechanical perspective, 45 degrees helical plating is associated with lower axial and varus/valgus displacement under axial loading and demonstrates comparable resistance to failure versus straight plating. Therefore, 45 degrees helical plates can be considered as a valid alternative to straight plates for treatment of proximal humeral shaft fractures.

Zurich Open Repository and Archive (University of Zurich)
Openalex Percentile: Top 46%
Species Distribution and Climate Change
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

45 degrees helical plates are a valid alternative to straight plates for treatment of proximal humeral shaft fractures · Zurich Open Repository and Archive (University of Zurich) (2025) | TGRS Research Map | TGRS