Biomechanical Characterization of Metacarpal Fixation: Internal Load Determination and Evaluation of a Novel Adhesive Osteosynthesis.

Metal plates are commonly used for the fixation of metacarpal fractures, but are associated with complications such as tendon adhesions that impair finger mobility. AdhFix, a novel osteosynthesis material, may reduce these complications, but its biomechanical performance in the metacarpal region remains untested. This study aimed to evaluate internal bending moments during postoperative rehabilitation and assess the biomechanical potential of AdhFix in treating comminuted metacarpal shaft fractures using a human cadaveric model. In five cadaveric hands, unstable shaft fractures of the second, third, and fourth metacarpals were simulated using a 3 mm osteotomy gap and stabilized with polyether ether ketone (PEEK) plates and stainless-steel cortical screws. A custom 3D-printed guide ensured accurate osteotomy and screw positioning. Tendon loading was simulated by pulling flexor digitorum profundus tendons until fingertip-to-palm contact was achieved, followed by wrist flexion using 100 N of force on the flexor carpi radialis and ulnaris tendons. Bending of the fixation was captured using stereographic imaging, and internal bending moments were calculated via finite element modeling. After removal of the PEEK plate, the procedure was repeated using AdhFix for fixation. Maximum internal bending moments were 6.14 ± 2.03 Nmm during finger flexion and 3.37 ± 1.64 Nmm during wrist flexion. AdhFix demonstrated mechanical integrity under both conditions with no observed failure. STATEMENT OF CLINICAL SIGNIFICANCE: AdhFix may provide a mechanically stable alternative to conventional plates during early rehabilitation, potentially reducing tendon adhesions and preserving finger mobility.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-07-30
DOI
https://doi.org/10.48620/90444
Primary Topic
Genomics and Phylogenetic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Characterization of Metacarpal Fixation: Internal Load Determination and Evaluation of a Novel Adhesive Osteosynthesis.

Open Access CRIS of the University of Bern
Genomics and Phylogenetic Studies
article

Biomechanical Characterization of Metacarpal Fixation: Internal Load Determination and Evaluation of a Novel Adhesive Osteosynthesis.

article en

Abstract

Metal plates are commonly used for the fixation of metacarpal fractures, but are associated with complications such as tendon adhesions that impair finger mobility. AdhFix, a novel osteosynthesis material, may reduce these complications, but its biomechanical performance in the metacarpal region remains untested. This study aimed to evaluate internal bending moments during postoperative rehabilitation and assess the biomechanical potential of AdhFix in treating comminuted metacarpal shaft fractures using a human cadaveric model. In five cadaveric hands, unstable shaft fractures of the second, third, and fourth metacarpals were simulated using a 3 mm osteotomy gap and stabilized with polyether ether ketone (PEEK) plates and stainless-steel cortical screws. A custom 3D-printed guide ensured accurate osteotomy and screw positioning. Tendon loading was simulated by pulling flexor digitorum profundus tendons until fingertip-to-palm contact was achieved, followed by wrist flexion using 100 N of force on the flexor carpi radialis and ulnaris tendons. Bending of the fixation was captured using stereographic imaging, and internal bending moments were calculated via finite element modeling. After removal of the PEEK plate, the procedure was repeated using AdhFix for fixation. Maximum internal bending moments were 6.14 ± 2.03 Nmm during finger flexion and 3.37 ± 1.64 Nmm during wrist flexion. AdhFix demonstrated mechanical integrity under both conditions with no observed failure. STATEMENT OF CLINICAL SIGNIFICANCE: AdhFix may provide a mechanically stable alternative to conventional plates during early rehabilitation, potentially reducing tendon adhesions and preserving finger mobility.

Open Access CRIS of the University of Bern
Plastic Surgery Hospital (CN)
Openalex Percentile: Top 54%
Genomics and Phylogenetic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Biomechanical Characterization of Metacarpal Fixation: Internal Load Determination and Evaluation of a Novel Adhesive Osteosynthesis. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS