Optimizing Reduction Guide Stability in Osteotomy Using Patient-Specific Instrumentation: A Basic Guideline

BACKGROUND The use of patient-specific instruments (PSIs) for osteotomies is becoming more popular in orthopaedic surgery for correcting mechanical axis and posttraumatic deformities. However, the PSI reduction guides have great potential for intraoperative deformation, which adversely affects the accuracy of the procedure. PURPOSE To conduct a finite element analysis (FEA) to analyze different design parameters to improve the intraoperative stability of the reduction guides. STUDY DESIGN Descriptive laboratory study. METHODS A reduction guide with a rectangular cross section and four 4-mm K-wire slots was simplified, and the following parameters were modified: width, height, profile design, K-wire thickness, and positions. Bending and torsional moments were applied to the guide construct and guide deformation and equivalent stress were determined using FEA. RESULTS Increasing the profile height by 25% resulted in a 44% reduction in guide deformation for bending (37% for torsion). A 25% increase in profile width led to an 18% deformation reduction for bending (22% for torsion). Transverse K-wire slots resulted in 51% less deformation in torsion compared with longitudinally oriented slots. Placing the central K-wire slots 25% closer to the osteotomy reduced guide deformation by 20% for bending and 11% for torsion. CONCLUSION The most effective methods to increase reduction guide stability are to increase the guide height and reduce the central K-wire distance to the osteotomy. CLINICAL RELEVANCE When performing opening or closing wedge osteotomies, which mainly involve bending of the guide, a high-profile guide and longitudinally oriented K-wire slots should be used. When torque is expected as in rotational osteotomies, the K-wire holes in guides should be oriented transversely to reduce intraoperative deformation.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2024-12-10
DOI
https://doi.org/10.5167/uzh-269092
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Reduction Guide Stability in Osteotomy Using Patient-Specific Instrumentation: A Basic Guideline

Zurich Open Repository and Archive (University of Zurich)
Bone fractures and treatments
article

Optimizing Reduction Guide Stability in Osteotomy Using Patient-Specific Instrumentation: A Basic Guideline

article en

Abstract

BACKGROUND The use of patient-specific instruments (PSIs) for osteotomies is becoming more popular in orthopaedic surgery for correcting mechanical axis and posttraumatic deformities. However, the PSI reduction guides have great potential for intraoperative deformation, which adversely affects the accuracy of the procedure. PURPOSE To conduct a finite element analysis (FEA) to analyze different design parameters to improve the intraoperative stability of the reduction guides. STUDY DESIGN Descriptive laboratory study. METHODS A reduction guide with a rectangular cross section and four 4-mm K-wire slots was simplified, and the following parameters were modified: width, height, profile design, K-wire thickness, and positions. Bending and torsional moments were applied to the guide construct and guide deformation and equivalent stress were determined using FEA. RESULTS Increasing the profile height by 25% resulted in a 44% reduction in guide deformation for bending (37% for torsion). A 25% increase in profile width led to an 18% deformation reduction for bending (22% for torsion). Transverse K-wire slots resulted in 51% less deformation in torsion compared with longitudinally oriented slots. Placing the central K-wire slots 25% closer to the osteotomy reduced guide deformation by 20% for bending and 11% for torsion. CONCLUSION The most effective methods to increase reduction guide stability are to increase the guide height and reduce the central K-wire distance to the osteotomy. CLINICAL RELEVANCE When performing opening or closing wedge osteotomies, which mainly involve bending of the guide, a high-profile guide and longitudinally oriented K-wire slots should be used. When torque is expected as in rotational osteotomies, the K-wire holes in guides should be oriented transversely to reduce intraoperative deformation.

Zurich Open Repository and Archive (University of Zurich)
Openalex Percentile: Top 49%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimizing Reduction Guide Stability in Osteotomy Using Patient-Specific Instrumentation: A Basic Guideline · Zurich Open Repository and Archive (University of Zurich) (2024) | TGRS Research Map | TGRS