Impact of scanning interruptions on accuracy of implant-supported full-arch scans: an in-vitro pilot study.

Purpose To assess the impact of involuntary interruptions (simulating tracking loss by moving the scanner out of its focal distance) and voluntary interruptions (pressing the scanner's turn-on button) on the accuracy of implant-supported full-arch scans using an intraoral scanner (TRIOS 5, version 22.1.10; 3Shape; Copenhagen, Denmark).Materials And Methods An edentulous model with four implants was digitized with an industrial scanner (Artec Micro II; Artec 3D) to create a reference scan. Four groups (n=30) were established based on the number of interruptions during scanning: Zero Group (no interruptions; control group), 6-V Group (six voluntary interruptions), 6-I Group (six involuntary interruptions), and 12-I Group (twelve involuntary interruptions). Primary outcome was accuracy assessed by the Root Mean Square (RMS) method. Secondary outcomes included scanning time and the number of photograms. Data were analyzed using one-way ANOVA and post hoc Tukey multiple comparison tests (α=.05).Results A total of 120 digital scans were conducted. The Zero group achieved a RMS error of 291 ±47 µm, a scanning time of 68 ±6s, and 1320 ±129 photograms. 6-V group significantly reduced RMS error (MD -102µm [IC 95%: -141, -63]), decreased scanning time (MD -20s [IC 95%: -25, -17]), and reduced photograms (MD -415 photograms [IC 95%: -506, -324]) compared to the control group (P<.001). Simulations of 6 or 12 involuntary interruptions did not affect accuracy compared to the control group (P>.05).Conclusions Voluntary interruptions during scanning, achieved by pressing the scanner's turn-on button, appear to enhance accuracy due to image preprocessing, while involuntary interruptions had no significant impact on the accuracy of implant-supported full-arch scans.Clinical Significance Voluntary stop during scanning implant-supported full-arches may result in better-fitting prostheses owing to higher scan accuracy and efficiency.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-12-30
DOI
https://doi.org/10.48620/78751
Primary Topic
Slime Mold and Myxomycetes Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of scanning interruptions on accuracy of implant-supported full-arch scans: an in-vitro pilot study.

Open Access CRIS of the University of Bern
Slime Mold and Myxomycetes Research
article

Impact of scanning interruptions on accuracy of implant-supported full-arch scans: an in-vitro pilot study.

article en

Abstract

Purpose To assess the impact of involuntary interruptions (simulating tracking loss by moving the scanner out of its focal distance) and voluntary interruptions (pressing the scanner's turn-on button) on the accuracy of implant-supported full-arch scans using an intraoral scanner (TRIOS 5, version 22.1.10; 3Shape; Copenhagen, Denmark).Materials And Methods An edentulous model with four implants was digitized with an industrial scanner (Artec Micro II; Artec 3D) to create a reference scan. Four groups (n=30) were established based on the number of interruptions during scanning: Zero Group (no interruptions; control group), 6-V Group (six voluntary interruptions), 6-I Group (six involuntary interruptions), and 12-I Group (twelve involuntary interruptions). Primary outcome was accuracy assessed by the Root Mean Square (RMS) method. Secondary outcomes included scanning time and the number of photograms. Data were analyzed using one-way ANOVA and post hoc Tukey multiple comparison tests (α=.05).Results A total of 120 digital scans were conducted. The Zero group achieved a RMS error of 291 ±47 µm, a scanning time of 68 ±6s, and 1320 ±129 photograms. 6-V group significantly reduced RMS error (MD -102µm [IC 95%: -141, -63]), decreased scanning time (MD -20s [IC 95%: -25, -17]), and reduced photograms (MD -415 photograms [IC 95%: -506, -324]) compared to the control group (P<.001). Simulations of 6 or 12 involuntary interruptions did not affect accuracy compared to the control group (P>.05).Conclusions Voluntary interruptions during scanning, achieved by pressing the scanner's turn-on button, appear to enhance accuracy due to image preprocessing, while involuntary interruptions had no significant impact on the accuracy of implant-supported full-arch scans.Clinical Significance Voluntary stop during scanning implant-supported full-arches may result in better-fitting prostheses owing to higher scan accuracy and efficiency.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Openalex Percentile: Top 66%
Slime Mold and Myxomycetes Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.